Customization: | Available |
---|---|
After-sales Service: | 24hours |
Warranty: | 24months |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Functional requirements:
1. Equipped with comprehensive operating bed, operating shadowless lamp and related equipment; Auxiliary devices such as oxygen supply system and air laminar flow purification device are installed to carry out early surgical treatment or emergency surgical operations, and the operating room reaches 10,000 purification standards. It can achieve appendectomy, stomach resection, enterotomy, thyroid resection, hernia incision, fracture internal fixation operation and gynecological delivery and other aseptic operations. With auxiliary vehicles such as shelter CT, brain stroke can be carried out
Pre-hospital first aid and health screening for middle and myocardial infarction.
2, optional vehicle generator set, with independent work ability, can carry out field emergency operations, can carry out 5-6 times a day, the first and second operations, three to four operations 2-3 times.
Main technical parameters
Overall dimensions: | 11965×2550×3660,3890(mm) | Fuel Type: | Diesel oil |
Gross Weight | 30000(Kg) | ||
Net weight | 29805(Kg) | Rated load | (Kg) |
Approach Angle/Departure Angle: | 19/11(°) | Front/rear overhang: | 1492/2523(mm) |
Axle Load: | 6200/6320/17480 | Wheelbase: | 1950+3800+1400,1950+4000+1400, 1950+4200+1400,1950+4600+1400, 1950+4800+1400(mm) |
Axle Number | 4 | Maximum speed: | 110(km/h) |
Tire Number | 12(PCS) | Tire Specifications: | 11.00R20 18PR,12R22.5 18PR,295/80R22.5 18PR,12.00R20 18PR,315/80R22.5 18PR |
Fuel consumption: | (L/100Km) | Number of spring pieces: | 3/3/-/-,4/4/-/- |
Front wheel track: | 2022/2022,2041/2041(mm) | Rear wheel track: | 1830/1830(mm) |
Engine | Engine manufacturer | Displacement (ml) | Power (kw)/ horsepower (ps) |
WP10.5H460E62;MC13.54-61;WP10.5H400E62;WP10H400E62;MC13.50-61;MC11.46-61;MC11.43-61;MC13.48-60;MC11.44-60;MC11.40-60;MC13.50-60;WP10.5H430E62;MC11.40-61;MC13.46-61;MC13H.51-61;MC13H.54-61;WP12.430E62;WP12.460E62;WP12.490E62;WP13.480E62;WP13.510E62;WP13.55 | Weichai Power Co., LTD. China Heavy Duty Automobile Group Co., LTD |
10520;12419;10520;9500;12419;10518; 10518;12419;10518;10518;12419;10520;10518;12419;13020;13020;11596;11596;11596;12540;12540;12540;12540;11050;11050;12419;11050 |
338;400;294;294;371;341;319;356;327;297;371;316;297;341;378;400;316;338;360;353;375;405;426;341;363;356;319 |
Engine model |
Engine manufacturer |
Displacement (ml) |
Power (kw) |
WP10.350E53 |
Weichai power |
9726 |
257 |
Technical requirements:
1, vehicle composition: second class chassis, aluminum alloy box
2, the operation car is divided into: equipment room, preparation room, operating room three areas; The front part is the equipment area, the middle part is the operation area, and the back part is the doctor preparation area and nursing area. Equipment room: equipped with air purification system and electrical system; The preparation room is located at the rear end, with a rear entrance, wash basin, testing table, mobile stretcher bed, 1 set of medicine refrigerator, 1 set of dressing cabinet, and 1 set of distribution cabinet. The circulation doors of the preparation room and operating room are electric doors. Operating room safety
Equipped with: comprehensive operating bed, operating shadowless lamp, wash basin, medical equipment fixing device.
3. Cleanliness of the central area of the operating room: ≥ 10,000, cleanliness of the preparation room: ≥ 100,000;
4. Vehicle function: The special function and device description of the parameters announced by the Ministry of Industry and Information Technology of the operating vehicle contain the words "operating bed, operating shadowless lamp, medical operation and other functions".
5, overall size (length * width * height mm) : ≥10000*2500*3600
6, maintenance quality (Kg) : 13000-25000.
7. Departure Angle/approach Angle (°) : ≥16/9.
8, front suspension/rear suspension (mm):≥1400/2700.
11. Number of axes: ≥2.
12. Number of tires :≥6.
13. Rear wheel base (mm) : ≥1820.
14, engine: straight six cylinders, water-cooled, supercharged intercooled, high pressure common rail.
15, power (kW) : ≥169.
16. Displacement (ml) : ≥6200.
17, the operation vehicle is a fixed shelter type, no water, suitable for field high temperature, cold, high altitude area; The compartment should be large plate, large plate square cabin assembly, extensible, double-side electric drive, but also in the case of no power supply can be manually completed cabin shrinkage.
18, compartment floor material requirements:
Odor requirements: wet (23ºC) odor grade ≤2.0 (provide test report)
Odor requirements: wet (40ºC) odor grade ≤2.5 (provide test report)
Odor requirements: Odor level ≤3.0 under dry state (80ºC) (provide test report)
Combustion characteristics requirements: The maximum combustion speed in an environment with 50% relative humidity (23 ° C) ≤A-0mm/min.
19, the car body is made of high-strength corrosion-resistant aluminum plate and square tube skeleton, welding and bonding process.
20, heat insulation requirements: body with heat insulation layer.
21, environmental requirements: medical cabin interior decoration materials need to be environmentally friendly materials.
22, doors and Windows: sealed.
23, door: back door to open 1, equipment cabin maintenance door 2.
24. 1 set of ladders: used for operation and maintenance between equipment.
25, hydraulic support system: four support legs share a set of hydraulic cylinders.
26, hydraulic lifting tailboard system (for rescued personnel on and off the vehicle) : the vehicle tailboard is set up with a set of hydraulic tailboard, the load is required to be ≥2 tons, can be landed, the material is steel. Set up ramp pedals and cart into the cabin. It must be firmly connected with the body structure or connecting parts, and has sealing.
27, tail plate surface size (length X width /mm) : ≥2200*1850.
28, the maximum lifting height (mm) : ≥1500.
29, the maximum load (kg) : ≥2000.
30, skirt box: The lower part of the car is installed with skirt cabin, skirt cabin is composed of skeleton and cabin door combination, skirt cabin skeleton is connected to the side wall of the cabin, and the whole cabin forms a whole, the skeleton is installed with cabin door, the cabin door is installed with gas spring, door lock, hinge, etc., the cabin door is an upturned door, the skirt door uses aluminum alloy hinge, the door and cabin are carbon steel material.
Air purification system
1, configure a set of air conditioning purification integrated system, installed in the equipment room. It is required that the doctor's preoperative preparation area and the patient's preoperative preparation area be purified in millions of levels. The operation area is purified at 100,000 level, including: air conditioning, purification unit, ventilation pipe, return air pipe, laminar ceiling at the end, high efficiency filter at the end, air volume control valve, pipe silencer, pipe insulation and fixing, temperature control system, etc.
2, cleanliness: 100,000-10,000.
3, room temperature: 18-26ºC.
4. Number of air changes (times /h) : ≥50.
5, operating room and outdoor pressure difference (Pa) : ≥20.
6, illumination (LM) : 200-300.
7, purification unit: The box adopts special insulation materials for the box, the box is equipped with a supply fan and a junior high efficiency filter, the air supply port is set up on the side of the purification unit box, and the top surface is installed with a return air port and a supply air port, the air supply fan will breathe the indoor air through the return air port to the purification unit box, and then through the primary, middle and high efficiency filter from the air supply port to the room, the reciprocating cycle to purify the operating room air.
8, the unit internal filtration: the initial effect filter: filter 0.5um particles; Efficiency: 40-50%; Bag type medium effect filter: filter 0.5um particles; Efficiency: 70-80%.
9. The end laminar flow ceiling is installed on the top of the operating room operating bed, and 6 high-efficiency filters are installed inside the laminar flow ceiling to filter 0.5um particles; Efficiency: ≥99.99%, the air from the air supply outlet of the purification unit passes through the air supply pipe and the air volume regulating valve to the high efficiency filter at the top of the operating room.
Each working area forms an internal circulation system. The operation area is equipped with fresh air, circulating air and exhaust air systems, and the return air of the air conditioner is connected to two working areas.
10. A high efficiency filter is installed at the top of the preparation chamber. The air coming out of the air supply outlet of the purification unit goes through the air supply pipeline and the air volume regulating valve to reach the high efficiency filter at the top of the high efficiency preparation chamber.
11. The air conditioner and the purification unit box are connected in series. The air conditioner is connected in series between the return air pipeline and the purification unit box. The air coming out of the air conditioner is filtered through the filter inside the purification unit and then served indoors to ensure the cleanliness of the indoor air.
Fresh air volume: ≥500m³;
Return air volume: ≥3000m³;
External residual pressure :≥800Pa;
Motor: low noise centrifuge;
Fan: frequency conversion, high static pressure;
Compressor: frequency conversion, single cooling type (8 pieces);
Indoor cooling capacity :≥19KW;
Electric auxiliary heat: ≥15KW;
Comprehensive maximum operating power: ≥22KW;
Comprehensive maximum starting current: frequency conversion starting;
Unit noise: ≤70dB;
Air supply mode: backward and upward;
Temperature control range: 22ºC~26ºC;
Moisture control range: 50%~60%;
Heat exchanger type: copper tube with aluminum fin;
Rated power: ≥22KW;
Control system: computer board, language customization (Chinese), touch screen; Throttle mode: electronic expansion valve.
12, the air volume control valve regulates the positive pressure difference between the operating room, the preparation room and the outside, and the pressure difference between the operating room and the preparation room. The purification unit is installed with a return air outlet and a supply air outlet, and the supply fan draws the indoor air through the return air outlet to the purification unit box, and then passes through the primary, middle and high efficiency filters from the air outlet to the room, and the reciprocating cycle purifies the air in the operating room.
Basic Parameters
Dimension (mm):11990*2500 (expanded 3800) *3990 |
Cabin dimension (mm):9307*3645*2105 |
Maximum total mass (kg) : 18245 |
Maximum speed (km/h) : 110 |
Number of passengers in the cab:3 |
Maximum net power (kW) : 245 |
Fuel type: diesel |
Ground clearance ≥280mm |
Chassis:SINOTRUCK SITRAK |
Gearbox:9-speed automatic |
Engine:MC07.34-50 |
Displacement (ml): 6870 |
Maximum net power (kW) : 245KW |
Maximum torque/speed (N.m/(R /min) : 1250/1200-1800 |
Extension Compartment System
Transmission mechanism: NMRV075 PS70 -- HD14 |
Reduction ratio: 60*8 |
Output speed (rpm): no load 3.75, load 3.1 |
Output torque (Nm):290 |
Extension width on both sides of the extension compartment (mm):650 |
Extension and recovery time of extension compartment (s): about 50 |
Electrical System
Supply power:220V alternating current or use vehicle-mounted generator |
Output voltage precision:≤5% |
Equipment:voltage protection device |
Waterway system
Water tank:80L water tank, 60L sewage tank |
Water pump:DP-100 micro diaphragm water pump |
Hand dryer:KV-8268A automatic high-speed hand dryer |
Hand sterilizer :KV-2012S |
1.Are you trading company or manufacturer ?
We are Group Corporation manufacturer ,have Group Factories Contractor.Don't worry,dear.We have joined the trade assurance,if the products have quality problems when you received them,the payments can be refund to you.