Customization: | Available |
---|---|
After-sales Service: | 24 |
Warranty: | 24 |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Customizing 3 Axles Hydrochloric Acid Tanker 29500L HCl Tanks Hydrochloric Acid Tank Trailer ( Steel Lined Rubber plastic LLDPE Chemical Liquid Tanker )
Hydrochloride Acid Tank Trailer 30T -60T Solusion Hydrogen Chlorate, Sodium Hydroxide,Acrylic ,Acetic Acid,Glacial Acetic Acid, Hydrogen Peroxide ,Propionic acid,
Steel Lined LDPE aslo for HCL(max 35%), NaOH (max 50%), NaCLO (max 10%), PAC (max 17%),H2SO4(60%,98%) ,HF ( 48%),H3PO4 (10%-85%),NH3. H2O,H2O2 (30%)
Ask for better price
Acid Tanker Trailer For Road Transport (Hydrogen Fluoride) Hydrofluoric Acid HF 48%
The pictures are for your reference only.
acid tank semitrailer 3axles 29000Liters,32000liters,33800liters
Hydrochloric acid tank semitrailer
Tank volume: 22.4 -33 cbm: ,NH3·H2O
Transport : Sulfuric Acid 60% Hydrochloride,Hydrochloric Acid, Dilute Sulphuric Acid ,Acetic Acid, Acrylic Acid Hydrochloride, Hydrogen Chlorate, Sodium Hydroxide,Acrylic
Acetic Acid, Glacial Acetic Acid, Hydrogen Peroxide
Propionic Acid, Ammonia
Truck Model | Chassis Model | m³ | Steel lined PE Tank | Steel Tank | Steel lined PE Tank Steel | Stainless Steel tank | Carbon Steel Tank | Aluminium alloy | Medium | ||
DTA5310GFWD9 TANK TRANSPORTER FOR CORROSIVE ARTICLES | DFL1311A9 | 19.36 | 18.5 | / | 5 | / | / | Sulphuric Acid | |||
DTA5160GFWLZ TANK TRANSPORTER FOR CORROSIVE ARTICLES | LZ1161RAPAT | 10.5 | 10.5 | 11.56/12 | 5 | 5 | 6 | Ammonia | 8600kg | ||
DTA5250GFWCA TANK TRANSPORTER FOR CORROSIVE ARTICLES | CA5250GYYP62K1L6T3E4 | 13.13 | 14 | / | 5 | / | / | Hydrochloric Acid | |||
DTA5311GFWLZ TANK TRANSPORTER FOR CORROSIVE ARTICLES | LZ1311QELAT | 22.73 | 20.5 | / | 5 | / | / | Hydrochloric Acid | 14300kg | ||
DTA5310GFWC4 TANK TRANSPORTER FOR CORROSIVE ARTICLES | CA5310GYYP66K2L7T4E4 | 19.88 | 22.3 | / | 5 | / | / | Hydrochloric Acid | |||
DTA5161GFWC4 TANK TRANSPORTER FOR CORROSIVE ARTICLES | CA1167PK2BE4A80 | 8.2 | 8.5 | / | 5 | / | / | Hydrochloric Acid | 7500kg | ||
DTA5110GFWDF TANK TYPE TRANSPORT VEHICLE FOR CORROSIVE ARTICLES | DFA1110SJ11D3 | 6.1 | 6.1 | / | 5 | / | / | Hydrochloric Acid | 5200kg | ||
DTA5312GFWCT4 TANK TRANSPORTER FOR CORROSIVE ARTICLES | CA1311P1K2L6T10BE4A80 | 17.7 | 18 | / | 5 | / | / | Hydrochloric Acid | 13260kg | ||
DTA5311GFWC TANK TRANSPORTER FOR CORROSIVE ARTICLES | CA5310GYYP63K1L6T4E4 | 19.2 | 20.5 | 21.6 | 5 | 5 | 6 | Ammonia | 14630kg | ||
DTA9400GFWA TANK SEMI-TRAILER FOR CORROSIVE GOODS | 18.83 | 18.5 | 20 | 5 | / | 6 | Sulphuric Acid | 7620kg | |||
DTA9407GFW TANK SEMI-TRAILER FOR CORROSIVE GOODS | Round tank | 35 | 37 | 39 | 5 | 5 | 6 | Ammonia | 10340kg | ||
DTA9401GFWC TANK SEMI-TRAILER FOR CORROSIVE GOODS | Round tank | 18.83 | 19.5 | 20.5 | 5 | / | 6 | Sulphuric Acid | 9360kg | ||
DTA9406GFW TANK SEMI-TRAILER FOR CORROSIVE GOODS | Round tank | 29.5 | 31 | / | 5 | / | / | Hydrochloric Acid | 11380kg | ||
DTA9401GFWA TANK SEMI-TRAILER FOR CORROSIVE GOODS | Round tank | 19.95 | 22 | 23.5 | 5 | / | 5 | Dilute Sulphuric Acid | |||
DTA9402GFW TANK SEMI-TRAILER FOR CORROSIVE GOODS | Round tank | 25.67 | 25 | 26.3 | 5 | 5 | 6 | Caustic Soda | |||
DTA9403GFW TANK SEMI-TRAILER FOR CORROSIVE GOODS | Round tank | 27.84 | 27.8 | / | / | / | 5 | Hydrochloric Acid | |||
DTA9400GFW TANK SEMI-TRAILER FOR CORROSIVE GOODS | Round tank | 19.98 | 18 | 20 | 5 | / | 6 | Dilute Sulphuric Acid | 7620kg | ||
DTA9350GFW TANK SEMI-TRAILER FOR CORROSIVE GOODS | Round tank | 23.82 | 23 | / | 5 | / | / | Hydrochloric Acid | |||
DTA5310GRYL4 FLAMMABLE LIQUID TANK TRUCK | LZ1311QELAT | 23.78 | / | 28.6 | / | 5 | 6 | Diesel Oil | 12200kg | ||
DTA5310GRYD10 FLAMMABLE LIQUID TANK TRUCK | DFL1311A10 | 29.15 | / | 30 | / | 5 | 6 | Hexane | |||
DTA5310GRYD9 FLAMMABLE LIQUID TANK TRUCK | DFL1311A9 | 29.15 | / | 30 | / | 5 | 6 | Hexane | |||
DTA5310GRYC4 FLAMMABLE LIQUID TANK TRUCK | CA5310GYYP63K2L6T4E4 | 29.25 | / | 29.5 | / | 5 | 6 | Hexane | |||
DTA5311GRYC4 FLAMMABLE LIQUID TANK TRUCK | CA5310GYYP66K2L7T4E4 | 28.46 | / | 29.5 | / | 5 | 6 | Hexane | |||
DTA5160GRYB4 FLAMMABLE LIQUID TANK TRUCK | BJ5163GYY-AB | 13.44 | / | 14.5 | / | 4 | 5 | Hexane | |||
DTA5250GRYBH4 FLAMMABLE LIQUID TANK TRUCK | BJ5253GYY-XA | 25.3 | / | 25 | / | 5 | 6 | Hexane | |||
DTA5160GRYD5 FLAMMABLE LIQUID TANK TRUCK | DFL1160BX5 | 14.22 | / | 17/17/15.13 | / | 4 | 5 | Hexane | |||
DTA5160GRYE4 FLAMMABLE LIQUID TANK TRUCK | EQ1168GLJ3 | 15 | / | 15.7/16.4/16.7 | / | 4 | 5 | Hexane | |||
DTA5310GRYB4 FLAMMABLE LIQUID TANK TRUCK | BJ5317GYY-XB | 28.45 | / | 29.8 | / | 5 | 6 | Hexane | |||
DTA5251GRYC4P62 FLAMMABLE LIQUID TANK TRUCK | CA5250GYYP62K1L6T3E4 | 17.09 | 19.7 | / | 4 | 5 | Butyl Acetate | 10420kg | |||
DTA5311GRYYBJ4 FLAMMABLE LIQUID TANK TRUCK | BJ5312GYY-XB | 21 | 21.7 | / | 4 | 5 | Butyl Acetate | 12800kg | |||
DTA9390GRY FLAMMABLE LIQUID TANK SEMI-TRAILER | 41.34 | / | 44.5 | / | 5 | 6 | Alcohol | ||||
DTA9401GRY FLAMMABLE LIQUID TANK SEMI-TRAILER | 45.25 | / | 43.5 | / | 5 | 6 | Ethanol | ||||
DTA9402GRY FLAMMABLE LIQUID TANK SEMI-TRAILER | 40.18 | / | 47.5 | / | 5 | 6 | Butanol | ||||
DTA9403GRYB FLAMMABLE LIQUID TANK SEMI-TRAILER | 45 | / | 44.5 | / | 5 | 6 | Butyl Ether | 8820kg | |||
DTA9401GRYD FLAMMABLE LIQUID TANK SEMI-TRAILER | 42.6 | / | 40.5 | / | 5 | 6 | Methanol | ||||
DTA9402GRYA ALUMINUM ALLOY FLAMMABLE LIQUID TANK SEMI-TRAILER | 42.39 | / | 47.8 | / | / | / | 9 | Methanol | |||
DTA9406GRY ALUMINUM ALLOY FLAMMABLE LIQUID TANK SEMI-TRAILER | 47.67 | / | 47.67 | / | / | / | 6 | Butyl Ether | |||
DTA9351GRY ALUMINUM ALLOY FLAMMABLE LIQUID TANK SEMI-TRAILER | Round tank | 36.87 | / | 36.5 | / | / | / | 9 | Methanol | ||
DTA9405GRYA ALUMINUM ALLOY FLAMMABLE LIQUID TANK SEMI-TRAILER | Announcement needs to be changed | 46 | / | 47.3 | / | / | / | 6 | Butyl Ether | ||
DTA9401GYYC ALUMINUM ALLOY OIL SEMI-TRAILER | 42 | / | 47 | / | / | / | 6 | Diesel Oil | 6800kg | ||
DTA9401GRYA ALUMINUM ALLOY FLAMMABLE LIQUID TANK SEMI-TRAILER | sample vehicle | 42 | / | 42 | / | / | / | 8 | Methanol | 7280kg | |
DTA9351GYY ALUMINUM ALLOY OIL SEMI-TRAILER | 43.5 | / | 39.9 | / | / | / | 6 | Gasoline | |||
DTA9401GYYB TYPE ALUMINUM ALLOY OIL SEMI-TRAILER | 47.5 | / | 49 | / | / | / | 6 | Gasoline | |||
DTA9400GSY ALUMINUM ALLOY EDIBLE OIL TRANSPORTATION SEMI-TRAILER | 43.8 | / | 43.5 | / | / | / | 6 | Edible Oil | |||
DTA5310GYYS4 ALUMINUM ALLOY TANKER | SQR1311D5T6-E1 | 28.2 | / | 30 | / | / | / | 6 | Gasoline | ||
DTA9400GYW TYPE TANK SEMI-TRAILER FOR OXIDIZING GOODS TRANSPORTATION | 27.3 | / | 32.5 | / | 6 | / | / | Liquid Ammonium Nitrate | 11650kg | ||
DTA9401GHY CHEMICAL LIQUID TRANSPORTATION SEMI-TRAILER | Round tank | 42 | / | 43.5 | / | 5 | 6 | Methanol | |||
DTA9402GY CHEMICAL LIQUID TRANSPORTATION SEMI-TRAILER | Round tank | 21.99 | 20 | 21.7 | 5 | / | 6 | Sodium Hydroxide | |||
DTA9405GHY CHEMICAL LIQUID TRANSPORTATION SEMI-TRAILER | 45.73 | / | 43.2 | / | 5 | 6 | Sec-Butylamine | ||||
DTA9406GHY CHEMICAL LIQUID TRANSPORTATION SEMI-TRAILER | 49.89 | / | 55.1 | / | 5 | 6 | Hexane | ||||
DTA9403GHY CHEMICAL LIQUID TRANSPORTATION SEMI-TRAILER | Round tank | 39.37 | / | 39.5 | / | 5 | 6 | Methanol | |||
DTA9407GY CHEMICAL LIQUID TRANSPORTATION SEMI-TRAILER | 33 | 33 | / | 5 | / | / | Diluted Hydrochloric Acid | ||||
DTA5251GHYDD CHEMICAL LIQUID TRANSPORT VEHICLE | DFL1250A11 | 21.45 | / | 22 | / | 5 | 6 | Xylene | |||
DTA9400GYY OIL SEMI-TRAILER | 47.7 | / | 51.5 | / | 5 | 6 | Gasoline | ||||
DTA5251GYYDD TANKER | DFL1250A11 | 21.6 | / | 20.5 | / | 5 | 6 | Gasoline | |||
DTA5310GFWD9 TANK TRANSPORTER FOR CORROSIVE ARTICLES | CA5250GYYP62K1L6T3E4 | 22.5 | / | 22/21.7 | / | 5 | 6 | Gasoline | |||
DTA5160GFWLZ TANK TRANSPORTER FOR CORROSIVE ARTICLES | DFL1311A10 | 27.65 | / | 29.6 | / | 5 | 6 | Gasoline | |||
DTA5250GFWCA TANK TRANSPORTER FOR CORROSIVE ARTICLES | CA5310GYYP63K2L6T4E4 | 28.5 | / | 30.4 | / | 5 | 6 | Gasoline | |||
DTA5311GFWLZ TANK TRANSPORTER FOR CORROSIVE ARTICLES | EQ1168GLJ3 | 14.24 | / | 15.7/16.3/16.6 | / | 4 | 6 | Gasoline | |||
DTA5310GFWC4 TANK TRANSPORTER FOR CORROSIVE ARTICLES | EQ1070 | 4.8 | / | 7 | / | 4 | 5 | Gasoline | 4270kg | ||
DTA5161GFWC4 TANK TRANSPORTER FOR CORROSIVE ARTICLES | Round tank | 29.9 | 31.5 | 33 | 5 | 6 | 6 | Sodium Hydroxide | |||
DTA5110GFWDF TANK TYPE TRANSPORT VEHICLE FOR CORROSIVE ARTICLES | 34.26 | / | 38.7 | / | 5 | 6 | Glycol | ||||
DTA5312GFWCT4 TANK TRANSPORTER FOR CORROSIVE ARTICLES | 31.5 | 33 | 36 | 5 | 5 | 6 | Water | ||||
DTA5311GFWC TANK TRANSPORTER FOR CORROSIVE ARTICLES | Round tank | 38.39 | / | 39 | / | 5 | 6 | Methanol Formaldehyde, | |||
DTA9400GFWA TANK SEMI-TRAILER FOR CORROSIVE GOODS | Round tank | 28.8 | 31.5 | 33 | 5 | 5 | / | Hydrogen Peroxide Solution |
The chemical compatibility of LDPE and HDPE on this chart is tested at 20°C: and 50°C: for 7 days and 30 days (if applicable) with constant exposure.
LDPE & HDPE resistance listed by chemical | |
1.4-dioxane | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50°C: shows some effect after 7 days. |
Acetaldehyde | LDPE / HDPE at 20°C: little or no damage after 30 days. HDPE at 50°C: shows some effect after 7 days. LDPE at 50°C: immediate damage may occur. |
Acetic Acid 5 % | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Acetic Acid, glacial 50% | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50 °C: immediate damage may occur. |
Acetone | LDPE / HDPE at 20°C-50°C: damage may occur. Not recommended for continuous use. |
Allyl Alcohol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Aluminum salts | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Amino acids | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ammonia | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ammonium carbonate saturated | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ammonium phosphate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ammonium sulphate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Amyl chloride | HDPE at 20°C: shows some effect after 7 days. HDPE at 50°C & LDPE at 20°C-50°C: immediate damage may occur. Not recommended for continuous use. |
Aniline | LDPE / HDPE at 20°C: little or no damage after 30 days. HDPE at 50°C: shows some effect after 7 days. |
Benzene | LDPE / HDPE at 20°C-50°C: damage may occur. Not recommended for continuous use. |
Benzyl alcohol | LDPE / HDPE at 50°C: immediate damage may occur. HDPE at 20°C: shows some effect after 7 days. |
Boric acid | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Bromine | LDPE / HDPE at 50°C: immediate damage may occur. HDPE at 20°C: shows some effect after 7 days. |
Butyric acid | LDPE / HDPE at 50°C: immediate damage may occur. HDPE at 20°C: shows some effect after 7 days. |
Calcium chloride | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Calcium hydroxide saturated | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Carbon tetrachloride | HDPE at 20°C: shows little or no damage after 30 days. LDPE at 20°C & HDPE at 50°C: show some effect after 7 days. LDPE at 50°C: not recommended. |
Chlorine 10% in water | LDPE / HDPE at 20°C: shows little or no damage after 30 days. LDPE at 50°C: shows damage and is not recommended. |
Chlorobenzene | Immediate damage may occur. Not recommended for continuous use. |
Chloroform | LDPE / HDPE at 20°C: show some effect after 7 days. LDPE / HDPE at 50°C: immediate damage may occur. Not recommended for continuous use. |
Chromic acid 10% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Chromic acid 50% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Citric acid 10% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Cresol | HDPE at 20°C: shows some effect after 7 days. LDPE at 20°C-50°C & HDPE at 50°C: show immediate damage. Not recommended for continuous use. |
Cyclohexane | LDPE / HDPE at 50°C: immediate damage may occur. LDPE / HDPE at 20°C: show some effect after 7 days. |
Diethyl ketone | LDPE / HDPE at 20°C-50°C: damage may occur. Not recommended for continuous use. |
Dimethylsulfoxide | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ethanol 95% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ethyl acetate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ethyl benzene | HDPE at 20°C: shows some effect after 7 days. LDPE at 20°C-50°C & HDPE at 50°C: show immediate damage. Not recommended for continuous use. |
Ethylene glycol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Ethylene oxide | HDPE at 20°C: shows little or no damage after 30 days. LDPE at 20°C: and LDPE/ HDPE at 50°C: show some effect after 7 days. |
Ferric chloride | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Fluoride | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Fluorine | HDPE at 20°C: shows little or no damage after 30 days. LDPE at 20°C: shows some effect after 7 days. Not recommended at 50°C. |
Formaldehyde 10% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Formaldehyde 40% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Glycerol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hexane | HDPE at 20°C: shows little or no damage after 30 days continuous use. HDPE at 50 °C: shows some effect after 7 days. LDPE not recommended at any temperature. |
Hydrochloric acid 20% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrochloric acid 35% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrochloric acid 5% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrocyanic acid | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrofluoric acid | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrofluoric acid 4% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrofluoric acid 48% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrogen peroxide 3% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Hydrogen peroxide 30% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Isobutyl alcohol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Isopropyl alcohol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Kerosene | LDPE / HDPE at 20°C: show some effect after 7 days. LDPE / HDPE not recommended at 50°C, as immediate damage may occur. |
Lactic Acid 10 % | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Lactic Acid 90 % | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Lead acetate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Methanol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Methyl ethyl ketone | Immediate damage may occur. Not recommended for continuous use. |
Methyl propyl ketone | HDPE at 20°C: shows some effect after 7 days. LDPE at 20°C-50°C & HDPE at 50°C: Immediate damage may occur. Not recommended for continuous use. |
Methylene chloride | HDPE at 20°C: shows some effect after 7 days. LDPE at 20°C-50°C & HDPE at 50°C: Immediate damage may occur. Not recommended for continuous use. |
Mineral oil | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50°C: may show immediate damage and is not recommended. |
n-amyl acetate | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50°C: shows some effect after 7 days or constant exposure. |
n-butyl alcohol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Nitric acid 50 % | LDPE at 20°C: shows little or damage after 30 days. HDPE at 20°C & LDPE at 50°C: show effect after 7 days. HDPE at 50°C: shows immediate damage and is not recommended. |
Nitric acid 70 % | LDPE / HDPE at 20°C: show some effect after 7 days. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
n-octane | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Oleic acid | HDPE at 20°C-50°C: little or no damage after 30 days. LDPE at 20°C-50°C: shows immediate damage and is not recommended. |
Oxalic acid | LDPE at 20°C: shows some effect after 7 days. HDPE at 20°C and LDPE / HDPE at 50°C: shows little/ no damage after 30 days. |
Ozone | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
Perchloric acid | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
Perchloric ethylene | LDPE / HDPE at 20°C-50°C: show immediate damage. Not recommended. |
Phenol | LDPE / HDPE at 20°C-50°C: show immediate damage. Not recommended. |
Phosphoric acid 10% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Phosphoric acid 85% | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50°C: shows immediate damage and is not recommended. |
Phosphorous trichloride | LDPE / HDPE at 20°C: little or no damage after 30 days. LDPE at 50°C: has no data available. HDPE at 50°C: shows some effect after 7 days. |
Potassium carbonate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Potassium hydroxide 5 % | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Potassium hydroxide concentrated | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Potassium permanganate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Propylene glycol | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Pyridine | Immediate damage may occur. Not recommended for continuous use. |
Salicylic acid, saturated | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Silver acetate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Silver nitrate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium carbonate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium chloride, saturated | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium dichromate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium hydroxide 1% | LDPE at 20°C-50°C: shows little or no damage after 30 days. HDPE at 20°C-50°C: shows some effect after 7 days. |
Sodium hydroxide 50% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium hypochlorite 15% | HDPE at 20°C-50°C: little or no damage after 30 days. LDPE at 20°C: is suitable but at 50°C: shows some effect after 7 days. |
Sodium nitrate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sodium sulphate | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sucrose | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sulfuric acid 20% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sulfuric acid 6% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sulfuric acid 60% | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Sulfuric acid 98% | LDPE at 20°C-50°C: shows little or no damage after 30 days. HDPE at 20°C: shows effect after 7 days. Not recommended for use at 50°C. |
Tannic acid | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Tetrahydrofuran | LDPE / HDPE at 20°C: show some effect after 7 day of constant exposure. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
Toluene | LDPE at 20°C: show some effect after 7 day of constant exposure. HDPE at 20°C-50°C & LDPE at 50°C: show immediate damage. Not recommended. |
Trichloracetic acid | LDPE / HDPE at 20°C: show some effect after 7 day of constant exposure. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
Trichlorethane | Immediate damage may occur. Not recommended for continuous use. |
Turpentine oil | LDPE / HDPE at 20°C: show some effect after 7 days. LDPE / HDPE at 50°C: show immediate damage. Not recommended. |
Urea | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Xylene | HDPE at 20°C: shows some effect after 7 day of constant exposure. LDPE at 20-50°C and HDPE at 50°C: show immediate damage. Not recommended. |
Zinc chloride | LDPE / HDPE at 20°C-50°C: little or no damage after 30 days. |
Customization, Cost Control Built How You Want it, at a Price You Can