• HCl Acid Liquid Transport Tanks (Hydrochloric Acid Tanks Acid Tanker Steel Lined PE Road Chemical Tank 16000L -17500L)
  • HCl Acid Liquid Transport Tanks (Hydrochloric Acid Tanks Acid Tanker Steel Lined PE Road Chemical Tank 16000L -17500L)
  • HCl Acid Liquid Transport Tanks (Hydrochloric Acid Tanks Acid Tanker Steel Lined PE Road Chemical Tank 16000L -17500L)
  • HCl Acid Liquid Transport Tanks (Hydrochloric Acid Tanks Acid Tanker Steel Lined PE Road Chemical Tank 16000L -17500L)
  • HCl Acid Liquid Transport Tanks (Hydrochloric Acid Tanks Acid Tanker Steel Lined PE Road Chemical Tank 16000L -17500L)
  • HCl Acid Liquid Transport Tanks (Hydrochloric Acid Tanks Acid Tanker Steel Lined PE Road Chemical Tank 16000L -17500L)

HCl Acid Liquid Transport Tanks (Hydrochloric Acid Tanks Acid Tanker Steel Lined PE Road Chemical Tank 16000L -17500L)

After-sales Service: 24
Warranty: 24
Condition: New
Customized: Customized
Tank Marerial: Metal Tank
Type: Horizontal / Vertical
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company, Group Corporation
  • Overview
  • Certifications
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
acid tanker
Storage Objects
Liquid
Materical
Q235A + PE (Plastic )16mm -22mm
Type H
Horizontal / Vertical
Transport Package
Nil
Specification
OEM
Trademark
Dong Run Ze
Origin
China
HS Code
73090000
Production Capacity
8000

Product Description

HCl Acid Liquid Transport Tanks (Hydrochloric Acid Tanks Acid Tanker Steel Lined PE Road Chemical Tank 16000L -17500L)

HCL Acid Liquid Transport Tanks for Truck lorry Customizing 5m3 - 25m3 ( Truck Mounted Tank body Carbon Steel inner Lined LLDPE )

  

Metal cans Steel-Lined Plastic
Transport Tank, Electrolytic Tank, Pickling Tank   Custom Made Rotationally Molded Linear Resins LLDPE
Custermizing Checmial Acid
Transport Tank 1-150 m3 Steel Lined LLDPE  Tank Used to Contain: HCl (max 35%) , Naoh (max 50%) , Naclo (max 10%) , PAC (max 17%) ,H2so4  
 

 Media (density) : (1155 Kg/m3), Hydrochloric Acid (1150 Kg/m3), Sulfate, Nitrate (1152 Kg/m3), Phosphate (1151 Kg/m3), Hydrofluoric Acid (1132 Kg/m3), Battery Fluid (1135 Kg/m3), Chloride (1135 Kg/m3), Ferric Chloride Solution (1130 Kg/m3), Sodium Hypochlorite (1130 Kg/m3), Sulfurous Acid (1030 Kg/m3)

processing/storing; aluminum sulfate, ammonium sulfate, calcium chloride, ethylene glycol, ferric chloride, ferric sulfate, ferrous sulfate, hydrochloric acid, hydrofluoric acid, hydrofluosilicic acid, hydrogen peroxide, magnesium chloride, phosphoric acid, polymers, potassium hydroxide, or just plain water and we'll design the Transport vessel(s) you require.

Transport HCL Acid Tanks Steel Lined LDPE  
For Transport Bleach, Hydrochloric Acid, Ferric Chloride, Oilfield Chemicals, Corrosive Wastes And Other Hazardous Cargoes. 
Steel ( 6 mm -8mm ) Lined PE Plastic 7042 (16mm - 25 mm ) Transport tank 

Steel Lined LDPE  Tank Transport HCL(max 35%), NaOH (max 50%), NaCLO (max 10%), PAC (max 17%),H2SO4(60%,98%) ,HF (48%),H3PO4 (10%-85%),NH3. H2O,H2O2 (30%) Hazardous Liquids Transport Tank  

  Steel Lined LDPE aslo for Transport  HCL(max 35%), NaOH (max 50%), NaCLO (max 10%), PAC (max 17%),H2SO4(60%,98%) ,HF ( 48%),H3PO4 (10%-85%),NH3. H2O,H2O2 (30%) 
Compounds, cleaning liquid, UN1760,  
Corrosive liquid, acidic, inorganic, n.o.s., UN3264,  
Corrosive liquid, acidic, organic, n.o.s., UN3265,  
Corrosive liquid, basic, inorganic, n.o.s., UN3266,  
Hypochlorite solutions, UN1791,  
Hydrochloric acid solution, UN1789,  
Sulfuric acid, UN2796,   
BATTERY FLUID, ALKALI UN 2797,

Detail Picture

HCl Acid Liquid Transport Tanks (Hydrochloric Acid Tanks Acid Tanker Steel Lined PE Road Chemical Tank 16000L -17500L)
HCl Acid Liquid Transport Tanks (Hydrochloric Acid Tanks Acid Tanker Steel Lined PE Road Chemical Tank 16000L -17500L)

HCl Acid Liquid Transport Tanks (Hydrochloric Acid Tanks Acid Tanker Steel Lined PE Road Chemical Tank 16000L -17500L)
HCl Acid Liquid Transport Tanks (Hydrochloric Acid Tanks Acid Tanker Steel Lined PE Road Chemical Tank 16000L -17500L)
HCl Acid Liquid Transport Tanks (Hydrochloric Acid Tanks Acid Tanker Steel Lined PE Road Chemical Tank 16000L -17500L)
HCl Acid Liquid Transport Tanks (Hydrochloric Acid Tanks Acid Tanker Steel Lined PE Road Chemical Tank 16000L -17500L)


HCl Acid Liquid Transport Tanks (Hydrochloric Acid Tanks Acid Tanker Steel Lined PE Road Chemical Tank 16000L -17500L)

ISO Tank

20FT T50 Liquid Chlorine Isotank Container Cl2 Un1017 Max Storage Pressure 1.5MPa 21670L

HCl Acid Liquid Transport Tanks (Hydrochloric Acid Tanks Acid Tanker Steel Lined PE Road Chemical Tank 16000L -17500L)


 

20FT 20000liters Stainless Steel Nitric Acid Hno3, Hf Acid, Naoh Sodium Hydroxide ISO Tank Container SS30408

HCl Acid Liquid Transport Tanks (Hydrochloric Acid Tanks Acid Tanker Steel Lined PE Road Chemical Tank 16000L -17500L)

 

20 Feet Q235B+PE Linging Acid Sodium Salt Liquid ISO Tank Container for Corrosive Sodium 3-Chloro-2-Hydroxypropanesulfonate 20kl Drilling Fluid Petrochemicals

HCl Acid Liquid Transport Tanks (Hydrochloric Acid Tanks Acid Tanker Steel Lined PE Road Chemical Tank 16000L -17500L)

 

Certifications

HCl Acid Liquid Transport Tanks (Hydrochloric Acid Tanks Acid Tanker Steel Lined PE Road Chemical Tank 16000L -17500L)

Packaging & Shipping

HCl Acid Liquid Transport Tanks (Hydrochloric Acid Tanks Acid Tanker Steel Lined PE Road Chemical Tank 16000L -17500L)

FAQ

1.Are you trading company or manufacturer ?

We are Group Corporation manufacturer ,have Group Factories Contractor.

2 .Can I have samples of this type of product to test the quality?
Yes, you can buy any sample to test the quality,our MOQ is 1 unit.

3. What's the delivery time and can you lower the price?
It depends on your order.The delivery time is within 30 workdays after we received your prepayment. If you have placed an order of large quantities, then,of course, the price can be lowered.
 
4.Can you supply some quick-wear parts?
Yes, we can supply the parts as your request,such as traction,traction pin,balance beam and plate spring,hanging accessories,turntable,all kinds of brake pads,brake pan, bearings,etc.
 
6.Do you have any used products for sale?
We have products in stock for choices,the prices are favorable,we'll show you our stock products if you need.

7.What's the payment terms?
TT 30% as deposit, balance before shipment by TT or at sight.

8. How to guarantee customers get the goods smoothly after they payment?
Don't worry,dear.We have joined the trade assurance,you can place the order by trade assurance,if we don't delivery products, the deposit will be returned to you.

9.How can you ensure the quality of the products?

Don't worry,dear.We have joined the trade assurance,if the products have quality problems when you received them,the payments can be refund to you.

 


Vertical Hydrochloric Acid Storage Tanks ,Dosing tank, Day tank 30cbm  (30000L) Draft 
Vertical Bleach  Sodium Hypochlorite ,Acid Storage Dosing Tanks 10cbm  (10000L) Draft 
Vertical Bleach  Sodium Hypochlorite ,Acid Dosing Tanks , measuring tank 5m3  (5000L) Draft 
Vertical Bleach  Sodium Hypochlorite ,Acid Dosing Tanks , measuring tank 2m3  (2000L) Draft 
metering tankVertical HCl Storage Tanks 90cbm  (90000L ,23775Gallon) Draft
Vertical Hydrochloric Acid Storage Tanks 50cbm  (50000L) Draft 
Vertical Hydrochloric Acid Storage Tanks 30cbm (30000L) Draft 
Vertical Hydrochloric Acid Storage Tanks 15cbm (15000L) Draft 
Vertical Hydrochloric Acid Storage Tanks 10cbm (10000L) Draft 
Vertical Hydrochloric Acid Storage Tanks 5000L Draft 


Rotationally Molded LLDPE TANK
 chemical resistance of LLDPE   
 Cell / :+8615271357675   
 tictrucks.en.made-in-china.com   

LDPE / HDPE Chemical Resistance Chart 

The chemical compatibility of LDPE and HDPE on this chart is tested at 20°C: and 50°C: for 7 days and 30 days (if applicable) with constant exposure.

LDPE & HDPE resistance listed by chemical
1.4-dioxane LDPE / HDPE at 20°C: little or no damage after 30 days.
LDPE at 50°C: shows some effect after 7 days.
Acetaldehyde LDPE / HDPE at 20°C: little or no damage after 30 days.
HDPE at 50°C: shows some effect after 7 days.
LDPE at 50°C: immediate damage may occur.
Acetic Acid 5 % LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Acetic Acid, glacial 50% LDPE / HDPE at 20°C: little or no damage after 30 days.
LDPE at 50 °C: immediate damage may occur.
Acetone LDPE / HDPE at 20°C-50°C: damage may occur.
Not recommended for continuous use.
Allyl Alcohol LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Aluminum salts LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Amino acids LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Ammonia LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Ammonium carbonate saturated LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Ammonium phosphate LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Ammonium sulphate LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Amyl chloride HDPE at 20°C: shows some effect after 7 days.
HDPE at 50°C & LDPE at 20°C-50°C: immediate damage may occur.
Not recommended for continuous use.
Aniline LDPE / HDPE at 20°C: little or no damage after 30 days.
HDPE at 50°C: shows some effect after 7 days.
Benzene LDPE / HDPE at 20°C-50°C: damage may occur.
Not recommended for continuous use.
Benzyl alcohol LDPE / HDPE at 50°C: immediate damage may occur.
HDPE at 20°C: shows some effect after 7 days.
Boric acid LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Bromine LDPE / HDPE at 50°C: immediate damage may occur.
HDPE at 20°C: shows some effect after 7 days.
Butyric acid LDPE / HDPE at 50°C: immediate damage may occur.
HDPE at 20°C: shows some effect after 7 days.
Calcium chloride LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Calcium hydroxide saturated LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Carbon tetrachloride HDPE at 20°C: shows little or no damage after 30 days.
LDPE at 20°C & HDPE at 50°C: show some effect after 7 days.
LDPE at 50°C: not recommended.
Chlorine 10% in water LDPE / HDPE at 20°C: shows little or no damage after 30 days.
LDPE at 50°C: shows damage and is not recommended.
Chlorobenzene Immediate damage may occur.
Not recommended for continuous use.
Chloroform LDPE / HDPE at 20°C: show some effect after 7 days.
LDPE / HDPE at 50°C: immediate damage may occur.
Not recommended for continuous use.
Chromic acid 10% LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Chromic acid 50% LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Citric acid 10% LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Cresol HDPE at 20°C: shows some effect after 7 days.
LDPE at 20°C-50°C & HDPE at 50°C: show immediate damage.
Not recommended for continuous use.
Cyclohexane LDPE / HDPE at 50°C: immediate damage may occur.
LDPE / HDPE at 20°C: show some effect after 7 days.
Diethyl ketone LDPE / HDPE at 20°C-50°C: damage may occur.
Not recommended for continuous use.
Dimethylsulfoxide LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Ethanol 95% LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Ethyl acetate LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Ethyl benzene HDPE at 20°C: shows some effect after 7 days.
LDPE at 20°C-50°C & HDPE at 50°C: show immediate damage.
Not recommended for continuous use.
Ethylene glycol LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Ethylene oxide HDPE at 20°C: shows little or no damage after 30 days.
LDPE at 20°C: and LDPE/ HDPE at 50°C: show some effect after 7 days.
Ferric chloride LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Fluoride LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Fluorine HDPE at 20°C: shows little or no damage after 30 days.
LDPE at 20°C: shows some effect after 7 days.
Not recommended at 50°C.
Formaldehyde 10% LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Formaldehyde 40% LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Glycerol LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Hexane HDPE at 20°C: shows little or no damage after 30 days continuous use.
HDPE at 50 °C: shows some effect after 7 days.
LDPE not recommended at any temperature.
Hydrochloric acid 20% LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Hydrochloric acid 35% LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Hydrochloric acid 5% LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Hydrocyanic acid LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Hydrofluoric acid LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Hydrofluoric acid 4% LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Hydrofluoric acid 48% LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Hydrogen peroxide 3% LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Hydrogen peroxide 30% LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Isobutyl alcohol LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Isopropyl alcohol LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Kerosene LDPE / HDPE at 20°C: show some effect after 7 days.
LDPE / HDPE not recommended at 50°C, as immediate damage may occur.
Lactic Acid 10 % LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Lactic Acid 90 % LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Lead acetate LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Methanol LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Methyl ethyl ketone Immediate damage may occur.
Not recommended for continuous use.
Methyl propyl ketone HDPE at 20°C: shows some effect after 7 days.
LDPE at 20°C-50°C & HDPE at 50°C: Immediate damage may occur.
Not recommended for continuous use.
Methylene chloride HDPE at 20°C: shows some effect after 7 days.
LDPE at 20°C-50°C & HDPE at 50°C: Immediate damage may occur.
Not recommended for continuous use.
Mineral oil LDPE / HDPE at 20°C: little or no damage after 30 days.
LDPE at 50°C: may show immediate damage and is not recommended.
n-amyl acetate LDPE / HDPE at 20°C: little or no damage after 30 days.
LDPE at 50°C: shows some effect after 7 days or constant exposure.
n-butyl alcohol LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Nitric acid 50 % LDPE at 20°C: shows little or damage after 30 days.
HDPE at 20°C & LDPE at 50°C: show effect after 7 days.
HDPE at 50°C: shows immediate damage and is not recommended.
Nitric acid 70 % LDPE / HDPE at 20°C: show some effect after 7 days.
LDPE / HDPE at 50°C: show immediate damage.
Not recommended.
n-octane LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Oleic acid HDPE at 20°C-50°C: little or no damage after 30 days.
LDPE at 20°C-50°C: shows immediate damage and is not recommended.
Oxalic acid LDPE at 20°C: shows some effect after 7 days.
HDPE at 20°C and LDPE / HDPE at 50°C: shows little/ no damage after 30 days.
Ozone LDPE / HDPE at 20°C: little or no damage after 30 days.
LDPE / HDPE at 50°C: show immediate damage.
Not recommended.
Perchloric acid LDPE / HDPE at 20°C: little or no damage after 30 days.
LDPE / HDPE at 50°C: show immediate damage.
Not recommended.
Perchloric ethylene LDPE / HDPE at 20°C-50°C: show immediate damage.
Not recommended.
Phenol LDPE / HDPE at 20°C-50°C: show immediate damage.
Not recommended.
Phosphoric acid 10% LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Phosphoric acid 85% LDPE / HDPE at 20°C: little or no damage after 30 days.
LDPE at 50°C: shows immediate damage and is not recommended.
Phosphorous trichloride LDPE / HDPE at 20°C: little or no damage after 30 days.
LDPE at 50°C: has no data available. HDPE at 50°C: shows some effect after 7 days.
Potassium carbonate LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Potassium hydroxide 5 % LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Potassium hydroxide concentrated LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Potassium permanganate LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Propylene glycol LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Pyridine Immediate damage may occur.
Not recommended for continuous use.
Salicylic acid, saturated LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Silver acetate LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Silver nitrate LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Sodium carbonate LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Sodium chloride, saturated LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Sodium dichromate LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Sodium hydroxide 1% LDPE at 20°C-50°C: shows little or no damage after 30 days.
HDPE at 20°C-50°C: shows some effect after 7 days.
Sodium hydroxide 50% LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Sodium hypochlorite 15% HDPE at 20°C-50°C: little or no damage after 30 days.
LDPE at 20°C: is suitable
but at 50°C: shows some effect after 7 days.
Sodium nitrate LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Sodium sulphate LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Sucrose LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Sulfuric acid 20% LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Sulfuric acid 6% LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Sulfuric acid 60% LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Sulfuric acid 98% LDPE at 20°C-50°C: shows little or no damage after 30 days.
HDPE at 20°C: shows effect after 7 days.
Not recommended for use at 50°C.
Tannic acid LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Tetrahydrofuran LDPE / HDPE at 20°C: show some effect after 7 day of constant exposure.
LDPE / HDPE at 50°C: show immediate damage.
Not recommended.
Toluene LDPE at 20°C: show some effect after 7 day of constant exposure.
HDPE at 20°C-50°C & LDPE at 50°C: show immediate damage.
Not recommended.
Trichloracetic acid LDPE / HDPE at 20°C: show some effect after 7 day of constant exposure.
LDPE / HDPE at 50°C: show immediate damage.
Not recommended.
Trichlorethane Immediate damage may occur.
Not recommended for continuous use.
Turpentine oil LDPE / HDPE at 20°C: show some effect after 7 days.
LDPE / HDPE at 50°C: show immediate damage.
Not recommended.
Urea LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.
Xylene HDPE at 20°C: shows some effect after 7 day of constant exposure.
LDPE at 20-50°C and HDPE at 50°C: show immediate damage.
Not recommended.
Zinc chloride LDPE / HDPE at 20°C-50°C: little or no damage after 30 days.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now