Customization: | Available |
---|---|
After-sales Service: | 24 |
Warranty: | 24 |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
HOWO Truck Mounted Power Supply Vehicle with 1200KW Generator
Product Features:
Chassis : ZZ1317V4667F1
Optional special equipment of the vehicle: generator set or diesel engine, sewage pump, control system, etc., mainly used for emergency rescue needs, emergency power generation, emergency rescue pumping sewage
Vehicle model |
5310XXH6 |
Chassis type |
HOWO |
Engine power |
327kw |
Quality of service |
30805kg |
Gross mass |
31000Kg |
Overall dimension |
11995×2550×3990mm |
Pump flow |
400-600m³/h (multiple portable submersible pumps are optional) |
Suction range of pump |
6-8.5 m |
Pump head |
10-25m |
Generator power |
50-90kw, 1200KW |
Configuration requirements |
Generator sets and pumps can be selected according to customer needs well-known brands |
Generators are a flexible power source, which makes them a valuable addition to job sites and disaster response teams. More and more commercial fleets are adding truck-mounted generators to their vehicles. This allows even more flexibility and convenience when it comes to power generation. Whether your trucks are used in construction, emergency response, disaster relief or transportation, there are many reasons to consider an integrated portable generator system.
Main technical parameters
Overall dimensions: |
11995×2550×3820,3890,3990(mm) |
Fuel Type: |
Diesel oil |
Gross Weight |
31000(Kg) |
||
Net weight |
30805,30870(Kg) |
Rated load |
(Kg) |
Approach Angle/Departure Angle: |
17/11(°) |
Front/rear overhang: |
1500/2570(mm) |
Axle Load: |
6500/7000/17500 |
Wheelbase: |
1950+4625+1350,1950+4600+1400, 2150+4625+1350,2150+4600+1400(mm) |
Axle Number |
4 |
Maximum speed: |
101(km/h) |
Tire Number |
12(PCS) |
Tire Specifications: |
11.00R20,12.00R20 18PR,12R22.5, 295/80R22.5,315/80R22.5 18PR |
Fuel consumption: |
(L/100Km) |
Number of spring pieces: |
11/11/12,4/4/12,11/11/-,4/4/- |
Front wheel track: |
2022/2022,2041/2041(mm) |
Rear wheel track: |
1500/2570(mm) |
Engine |
Engine manufacturer |
Displacement (ml) |
Power (kw)/ horsepower (ps) |
MC11.44-60;MC11.40-60;MC11.36-60;WP10H400E62; WP10.5H430E62;WP10.5H460E62 |
China Heavy Duty Automobile Group Co., LTD.; Weichai Power Co., Ltd. |
10518;10518;10518; 9480;10518;10518 |
327;297;268;294;316;338 |
Chassis 8X4
Alternating-Current Generator;
Diesel Engine;
Silent type modified carriage;
Electric power cable winch;
Hydraulic support device during the vehicle parking;
Engineering alarm lights (not installed when supplied, the specific installation time will be notified by the purchaser);
Reversing image system;
Coolant passage;
electron speed regulator;
Turbocharger;
Control system and protection system (including signal monitoring sensor, start, charging, display device and instrument);
24V lead-acid battery pack and automatic charging device;
Generator output circuit breaker;
Expansion and shock absorption joints;
The seat shock absorber;
Exchangeable air cleaner;
Oil and diesel oil filter;
exhaust muffler;
Damable parts required within 1000 hours;
The connection cable between the power supply unit and the output circuit breaker, the output fast navigation plug and the load output connection cable are 50 m 14 YCW (1 * 240 mm2) Single core copper core rubber set flexible cable (4 A, B, C phase, 2 N phase), this part of the cable and generator unit output fast plug (specification 800A), etc., this part of the cost are included in the power car quotation;
22) The unit should be equipped with accessories (the manufacturer of the manufacturer); pipe connection, equipped with test oil, lubricating oil and other consumables;
23) The tender quotation includes the 6-hour test cost of site full load (including resistance load, fuel, test instrument, etc.). The winning bidder shall provide test fuel, test instrument and the test test load, and the test method shall be approved by the purchaser. Test the main parameters of the purchased equipment according to the type test and test items of the purchased equipment, and issue the test report. All fees are included in the power supply car quotation;
24) Routine maintenance of the generator set for three years (once a year) (maintenance content includes: oil replacement, antifreeze, three filter, etc.), labor costs and all material costs are included in the quotation range;
25)Provide 0 # diesel 2000L and added to the tank when accepted and delivered;
26) Single-core copper core rubber sleeve flexible cable required for unit grid-connected power supply and emergency power supply station (240mm2), Rapid air insertion (800A) ;
27) Another 4 electric winches and 110KW diesel generator set for electric winches.
Generator Set |
1) Common power:≥1200KW; 2) Rated voltage: 690V; 3) Rated current:≥1,250 A; 4) Rated frequency: 50H; 5) Rated power factor: COS=0.8 (lag); 6) Steady-state voltage adjustment rate:≤1%; 7) Transient voltage adjustment rate: -15%~ + 20%; 8) Voltage stabilization time: ≤1.5 sec; 9) Voltage volatility: ≤0.5%; 10) Steady-state frequency adjustment rate: ≤3%; 11) Transient frequency adjustment rate: -10%~ + 15%; 12) Frequency stability time: ≤3 sec; 13) Frequency volatility: ≤0.5%. |
Diesel Engine |
1, Rated power: ≥1280KW, maximum power: ≥1420KW; 2, Rated speed: 1500 r/min; 3, model: four-stroke, V, 16 cylinder; 4, air intake mode: exhaust gas turbocharging, medium cooling; 5, exhaust system: using industrial muffler, exhaust outlet noise within 75dB. The engine and the silencer are connected with stainless steel flexible bellows. Meet the domestic environmental protection indicators, NO2Value of ≤2,000 mg / m3, The engine SO2, nitrogen oxide, flue gas and other major pollutants emissions must meet the standards; 6. Cooling mode: closed circulating water cooling, with water tank fan heat dissipation; 7. Speed regulation mode: electronic speed regulation; 8. Fuel consumption rate is <210g / Kwh (100% load), and oil consumption rate ≤0.5g / Kwh; 9. The cooling tank fan is used for the original engine; 10. Oil injection mode: PT direct injection system; 11. The engine has the function of fault self-diagnosis, and the LCD directly displays the fault code for easy maintenance and maintenance; 12, the engine has 24V DC start motor, starting motor 24 VDC / 1 x 7.5 kW; 13, the displacement of ≥50 liters; 14, the engine has a high-strength metal material oil pan; 15. Diesel engine overhaul time ≥20,000 hours. Note: engine brands: MTU, PERKIN , CUMMINS |
Generator |
The motor adopts no brush bearing motor, the main controller of the unit is displayed in Chinese, and it shall have perfect protection function and communication interface. 1. Rated power: ≥1200KW, with constant load operation under a certain insulation level, it is allowed to overload for 1 hour every 12 hours, and the maximum power is allowed to overload by more than 10%; 2. Rated frequency: 50Hz; 3. Rated voltage: three-phase AC: 690V; 4, Excitation mode: brushless self-excitation; 5. Voltage regulation: automatic voltage regulation AVR; 6, phase number: three-phase four-wire system; 7. Protection level: IP 23; 8. Insulation level: Grade H insulation; 9. Waveform distortion rate: ≤4%; 10, short circuit current capacity: 300%, 10S; 11. Overspeed capacity: ≥2250rpm; 12. Provide 30KW / 400V voltage stabilizing power supply and power distribution cabinet for the use of winch and external equipment; 13. Telephone impact factor (TIF) is less than 50, and electromagnetic effect (THF) is less than 2%. |
|
Generator Set Control System |
1. The control screen must have the following operation function buttons: start, stop, manual mode, automatic mode, test mode, alarm silencing, five-key menu navigation button, emergency stop button, test light / reset button. The control system is required to have the function of parallel machine, which can realize grid connection with the existing generator set of the purchaser, and reserved parallel machine interface; 2. The control screen must have the following status indicator lights: shutdown state, manual mode state, automatic mode state, test mode state, normal power generation, power generation power supply state, normal city power, city power supply state, remote start signal, fault signal, high water temperature, low oil pressure, overspeed; 3, the control screen must display the following unit operating parameters: three-phase voltage, three-phase current, frequency, power factors, apparent power, active power, reactive power, power degree meter (Kwh, Kva. H, Kvarh), engine speed, oil pressure, cooling water temperature, battery voltage, operation hours, engine start times, oil temperature, charge air pressure; 4. The control screen must have the function of fault event logging and ≥100 event records for easy fault search and maintenance. 5. The unit controller must communicate with the control unit of the electric injection engine to display the start fault code information and the engine operation parameters; 6. The control screen has the functions of automatic start and shutdown, and has automatic and manual shutdown functions; including but not limited to the following alarm or shutdown functions: Generator voltage is too high, too low- - - -shutdown oil pressure is low- - - - - - -alarm Generator frequency is too high, too low- - - - - - - - - -the shutdown water temperature is high- - - - - - - - - - -alarm The oil pressure is too low- - - - - - - - - - -shutdown generator overload- - - - - -alarm Three start failure- - - - - - - - - - - -shutdown high battery voltage- - - - - - -alarm Overspeed- - - - - - - - - - - - - - - - - - - - - - -shutdown low battery voltage- - - - - - -alarm Water temperature too high- - - - - - - - - - - - - - -shutdown fuel oil level low- - - - - - -alarm 7, with the function of oil machine start delay time adjustable, 0~60 seconds; 8, with the function of oil machine shutdown delay time adjustable, 0~60 seconds; 9, LCD LCD display, pixel ≥132X64, support multi-language display; 10. Protection grade ≥IP65; 11. It can be connected to the computer through USB interface to facilitate parameter setting; 12. After installing the expansion module, it can remotely start, stop and monitor through the APP program; 13. With the function of grid connection, install the data interface, and be compatible with the existing equipment of the purchaser when the controller is connected to the grid. |
|
Generator Set Output Switch Cabinet |
Electric operation (can be used), one with a standby. The maximum current of circuit breaker ≥2000 and the setting current of circuit breaker ≥1600. |
|
Technical Requirements For Daily Fuel Tank |
1. The daily fuel tank for at least 8 hours; 2. Material of fuel tank: carbon steel, steel plate thickness not less than 3mm; 3. The oil tank shall be treated with corrosion and rust, with at least one primer and two topcoats, and the paint color shall be determined by the bidder; 4. The fuel tank should be equipped with an access port, and the access port should have a dust cover plate; 5. The fuel tank should have a liquid level indicator and an indicator to close the valve; 6. The oil tank shall be equipped with a level gauge for automatic refueling system. The level meter shall use passive contact, and the level meter shall include low, high and super high oil levels. The level meter shall be easy to assemble; 7. Fuel tank accessories: fire resistance respirator, a full set of valves, connecting flanges (one set for each connecting port), connecting bolts. Note: Valve and flange size shall be determined by the bidder according to the oil supply system of the whole generator set. |
|
Technical Requirements For The Vehicle-Mounted System |
Outside the carriage |
1. Process: the appearance of the box body shall be flat, the width lamp shall be installed at the front corners of both sides of the roof, and waterproof and anti-seepage measures should be set at each door; the box body shall set or reserve corresponding doors or internal channels to facilitate the daily maintenance and operation of the unit; the corresponding shock absorption device between the box frame and the chassis; the daily operation of the generator set should be completed inside the box, and the service life of the box shall be more than 10 years; 2. It shall have the functions of fire prevention, flame retardant, rain prevention, snow prevention, dust prevention, rust prevention, heat insulation, noise reduction and shock insulation, long-term seismic structure, high outer strength, smooth surface treatment, reasonable vehicle configuration, lighting and fences; multi-stage noise reduction and environment-friendly noise reduction materials for long time.(Car body with high strength, light quality, small welding volume as the first choice); 3. Side doors and steps: The box body should be equipped with a side door and a convenient step to step up and down the car or small activity ladder, the step and straight ladder position should be arranged reasonably; 4. Emergency stop switch: the emergency stop switch should be set on the outside of the box, which is easy to shut down when the unit is abnormal; 5. Car structure of integrated steel structure design, material is not less than 2mm fine cold plate, the middle skeleton using rust-treated steel pipe welding, interior spray punching steel plate, the inside and outer layer filled with environmental protection flame retardant cotton, bus technology and high-grade paint; door body steel plate thickness is not less than 3mm, the box surface is smooth and smooth, surrounding edges and Angle. Each door opening of the box body should be set up with waterproof, anti-seepage measures; 6. Spray the surface of the carriage with poly paint (the specific color is engineering yellow), and spray the words "Urban drainage" in prominent positions on both sides of the carriage. The font and color are black, and the cost is included in the tender quotation; 7. The unit installation structure is reasonable and orderly; with seismic function, spacious space and convenient for maintenance and operation; 8. According to the carrying capacity of the vehicle, the vehicle chassis should be equipped with a hydraulic support system, and each support part of the support system should be able to be adjusted separately; 9. The operation panel is installed on the side of the car, and the operator is standing on the ground for convenient operation; 10. Rain-proof and dust-proof aluminum alloy blinds, equipped with a ladder for maintenance on the roof. |
Inside the carriage |
1. The overall layout of modified vehicle equipment and equipment: in the overall layout of the power supply vehicle, the generator set should be protected by the engine in transportation and use, so as to reduce the failure of the engine, extend the service life of the unit, and have a reasonable space for unit maintenance. And leave a reasonable fuel tank, cable winch, basic daily maintenance operations and other operating space. The counterweight requirement of the whole vehicle is reasonable. With a reasonable inlet and exhaust air and smoke exhaust system. The power supply car is required to be used in all-weather conditions. The power loss of the generator set after the vehicle modification shall not exceed 5%. 2. Lighting equipment: explosion-proof fluorescent lamp and emergency lights shall be provided in the compartment; AC / DC lighting system and municipal power combined explosion-proof AC power outlet which meet the explosion-proof requirements. When the unit is not started, the DC lighting system is used. AC / DC lights installed inside the box for easy operation, AC / DC separation, control box with 80A circuit breaker; all wiring inside the box shall be flame retardant pipe (groove), and all cables shall be waterproof, oil resistant and flame retardant cables. 3. Fire fighting equipment: the structure of the muffler should avoid fire accumulation, and dry powder fire extinguishers should be equipped in the compartment and installed in a place easy to use. 4. Cable release device: electric / manual cable winch and accessories should be set inside the box body, a total of four sets, electric and locking function. Two of them can wrap 750 m load cables, Seven compartments, One set is installed in the power supply car, One set is provided to the purchaser and equipped with one 10 kW diesel generator set (see below) for winch power supply; The other two sets can wrap 4 load cables, Four compartments, Install the corresponding number of nylon universal wheels according to the maximum load weight of the winch, Provide to the purchaser to place matching cables, All winches shall be wrapped by the purchaser, Cable selection per unit cross-sectional area load capacity, high temperature resistance grade of flame retardant rubber sleeve flexible cable, And should adopt a single-phase split disk layout, If the single-phase current is relatively large, The form of single-phase multiple separation should be adopted, A, B and C, N item 2 root, Its cross-sectional area shall meet the requirements of the unit operation, Power supply car supporting cable for 14 cables, A single cable shall not be no less than 50 meters. 5. The connection between the output cable of the power car and the output end of the generator set is a quick connector. The quick connector shall meet the operation requirements of the unit and the technical conditions of the product, and shall be common with the quick connector originally purchased and installed by the purchaser. 6. The partition shall be laid on the ground with the lower edge of the unit base, and the partition shall be no less than 5mm thick aluminum plate with anti-skid pattern, closed cable running channel and closed in the partition layer. 7. All the electrical wiring in the carriage is reasonable and beautiful, and through the PVC flame retardant insulation pipe. 8. Car tank should be set inside, the tank should be equipped with 12V electric refueling device set, reserved for operation convenient daily refueling outlet and sewage outlet, box should set the corresponding compartment or take other measures to ensure that the unit operation, the tank capacity should meet the unit fully load for at least 8 hours and meet the relevant fire control requirements. 9. Technical requirements for diesel generator set (10kw) 1) Generator Phase number: three phase / single phase Rated output: not less than 10 kVA Maximum output: not less than 11 kVA Power factor: not less than COS φ 0.8 Rated voltage: 380V / 220V Rated current: not less than 15.2A Speed and frequency: 3000rpm (50Hz) DC output 2) Engine Engine type: four-stroke, three-cylinder diesel engine Displacement: not less than 719CC Rated power: not less than 11.5kw/3000rpm Start mode: electric start Tank capacity: not less than 32L Continuous working hours: not less than 8.8 hours Lubricating oil capacity: not more than 3.1 liters 3) Attached devices AC overload protection: fuse-free circuit breaker (NFB) Fuel meter: there is Voltage meter: have Operation Schedule: Yes Output indicator light: Yes Preheated indicator light: Yes Oil alarm lamp: Yes Water temperature alarm lamp: yes Battery charging indicator light: Yes 4) Other Size (length * width * height):≤1025×645×950mm (including wheels) Net weight:≤266kg (including wheels) Battery capacity: 12V-45 AH |
|
Other requirements |
1. Low noise design, the allowable noise value of on-board generator shall comply with the provisions in the following table:
Note 1: Noise value at 1m of the on-mounted generator Note 2: Noise value at 7m of the vehicle generator vehicle 2. Equipped with power generation room, inlet and exhaust air sound muffler room, double muffler, equipped with explosion-proof lights, working lights, double pipe pneumatic system, fire extinguisher, vehicle taillight components, internal in and out, tool kit. 3. Air inlet, exhaust outlet, filling outlet and sewage outlet, air inlet and exhaust outlet are not in the same direction, with insulation door and step ladder. The inside and outside of the generator set liquid (lubricating oil, fuel oil, antifreeze) and sewage outlet should be set for the daily maintenance of the unit. The sewage outlet should be set under the vehicle chassis or under the box.(Ensure at the lowest chassis) 4. Connect the dual exhaust smoke and noise elimination system, fuel system, charger, self-start signal line, lighting and other electrical systems. 5. Diesel generator set is directly grounded with neutral point; the equipment shall have good grounding device and be marked with specified symbols or figures. The vehicle shall be equipped with a grounding bar with a length of not less than 0.6m and a grounding wire of not less than 20m.(Ground wire with insulation sheath, the cross-sectional area is not less than 25mm2) 6. Equipped with a coolant heating system. 7. The main components of the invested diesel engine, generator and control system are compatible with the existing equipment of the purchaser. |
Unit power P (Main)KW |
Noise level dB (A) |
Noise level dB (A) |
P≤200 |
≤72 |
≤67 |
200 |
≤76 |
≤71 |
P>500 |
≤80 |
≤75 |
single-core rubber sleeve flexible cable
1) Specification and model: YCW1X240mm2
2) Length: 500 m power supply
The rated voltage of the cable Uo / U is 0.6 / 1KV, and the long-term allowable working temperature of the cable shall not exceed 65ºC;
Cable structure is reasonable, soft, wear-resistant, high mechanical strength. Have climate resistance and certain oil resistance, suitable for outdoor or contact with oil occasions use
Basic parameters of generator set specifications : Output: 150KVA/120KW Frequency ( HZ ): 50 Unit model: DPS-120 Unit configuration: Shangchai equipped with Deco Rated current ( A ): 216 Rated voltage ( V ): 400/230 Unit weight ( Kg ): 1400 Unit size ( mm ): 2850*900*1100 |
Product model | DRZ5155XDY |
Chassis | Sino truck Howo Japan Brand I.SUZU |
Overall dimensions L×W×H mm |
9100x2550x3610, 3850 |
Displacement (L) | 6.8 |
Fuel | Diesel |
Wheelbase (mm) | 5000 |
Diesel generators equipped (Kw) | 80-300 |
1.Are you trading company or manufacturer ?
We are Group Corporation manufacturer ,have Group Factories Contractor.Don't worry,dear.We have joined the trade assurance,if the products have quality problems when you received them,the payments can be refund to you.
Hubei Dong Runze Special Vehicle Equipment Co., Ltd. Keystone Vessel (Wuhan) Co., Ltd ;Keystone Vessel Manufacturing Co., Ltd.