• Dry Powder Carbon Dioxide Fire Extinguisher Filling Machine
  • Dry Powder Carbon Dioxide Fire Extinguisher Filling Machine
  • Dry Powder Carbon Dioxide Fire Extinguisher Filling Machine
  • Dry Powder Carbon Dioxide Fire Extinguisher Filling Machine
  • Dry Powder Carbon Dioxide Fire Extinguisher Filling Machine
  • Dry Powder Carbon Dioxide Fire Extinguisher Filling Machine

Dry Powder Carbon Dioxide Fire Extinguisher Filling Machine

Application: Cleaning, Detergent, Fire Extinguisher Powder,Carbon Dioxide Filling,
Material Type: Liquid
Automatic Grade: Automatic
Driven Type: Electric
Transport Package: Wood Box
Specification: OEM
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company, Group Corporation

Basic Info.

Model NO.
Fire Extinguisher Filling Machine
Trademark
DRZE
Origin
China
HS Code
8422301090

Product Description

 Dry Powder Carbon Dioxide Fire Extinguisher Filling Machine  

Automatic Type Fire Extinguisher Powder Filler (Fire Extinguisher Production or Maintenance Machine)  Automatic Filling Fire Extinguisher

Test pressure and cleaning machine  
Carbon Dioxide Filling Machine GTM-B  
Carbon Dioxide Filling Machine GTM-D 
Powder Filling Machine GFM16-1B   
Powder Filling Machine GFM16-1
Automatic Filling Fire Extinguisher GFM8-2
Hydrostatic Testing Machine MSJ-12 
Air Pressure Testing Machine MQJ-8
Text Pressure and Cleaning Machine
Fire Extinguisher Clamper pneumatic
Fire Extinguisher Clamper manual

Dry Powder Carbon Dioxide Fire Extinguisher Filling Machine
Dry Powder Carbon Dioxide Fire Extinguisher Filling Machine
Dry Powder Carbon Dioxide Fire Extinguisher Filling Machine
Dry Powder Carbon Dioxide Fire Extinguisher Filling Machine
Dry Powder Carbon Dioxide Fire Extinguisher Filling Machine
Dry Powder Carbon Dioxide Fire Extinguisher Filling Machine
Dry Powder Carbon Dioxide Fire Extinguisher Filling Machine
Dry Powder Carbon Dioxide Fire Extinguisher Filling Machine
Dry Powder Carbon Dioxide Fire Extinguisher Filling Machine
Dry Powder Carbon Dioxide Fire Extinguisher Filling Machine
Dry Powder Carbon Dioxide Fire Extinguisher Filling Machine

Automatic Type Fire Extinguisher Powder Filler Gfm8-2 (Carbon Dioxide Filling Machine


Dry Powder Carbon Dioxide Fire Extinguisher Filling Machine
 
Machine Picture Model Technical Parameters and Price





 








GFM8-2

Advance features

1. Filling Continuously and automatically.

2. Good to environment by using powder tank.

3. High accuracy filling by using electronic weighing scale

4. Long using period by adopting filters.


Technical parameters
Power 0.55KW/1.5KW
Voltage 380V/220V Filling precision1Kg≤0.02 Filling Speed6-12kg/min Weight 200Kg
Overall size1130X520X1350mm


122*61*139cm 1.03m3
255kg
EXW $5360USD

Automatic type
fire
extinguisher
powder filler




 
 

Advance features

1. Easy operation and maintenance.

2. Small weight and movable.

3. Height adjusting by manual wheel.




GFM16-1B
Fire extinguisher powder filler
Technical parameters Power 1.1KW Voltage 220V
Filling precision1Kg≤0.02 Filling Speed5kg/min Weight90Kg
Overall size800X400X1350mm
   
  92*56*136cm 0.7m3
160kg
 
   

Advance features

1. Easy operation and maintenance.

2. Small weight and movable.

3. Height adjusting by manual wheel.




Fire extinguisher powder filler (stainless
Technical parameters Power 1.1KW Voltage 220V
Filling precision1Kg≤0.02 Filling Speed5kg/min Weight90Kg
steel type) Overall size800X400X1350mm
   
  92*60*137cm 0.8m3
158kg
 


 
 

Advance features

1. Easy operation and maintenance.

2. Small weight and movable.

3. Height adjusting by manual wheel.



GFM16-1
Fire extinguisher powder filler
Technical parameters Power 1.1KW Voltage 220V
Filling precision1Kg≤0.02 Filling Speed5kg/min Weight90Kg
(common type) Overall size800X400X1350mm
   
  92*60*137cm 0.8m3
158kg
 




 
 

Advance features

1. Easy operation and maintenance.

2. Small weight and movable.

3. Height adjusting by manual wheel.




GFM16-1A
Fire extinguisher powder filler
Technical parameters Power 1.1KW Voltage 380V/220V
Filling precision1Kg≤0.02 Filling Speed4kg/min Weight90Kg
Overall size800X400X1350mm
   
  92*56*129cm 0.66m3
158kg
 








 
  Specifications
Filling time and error table list




GTM-D
 
Co2 filling machine Voltage 220V 50Hz Filling pressure3 to 10 Mpa
Environment temperature 5ºC-45ºC
Frozen arrange more or less 10 ºC -15 ºC
compared with the environment temperature.
   
  120*80*132cm 1.27m3
208kg
 













 
  Filling time and error table list







GTM-C
Pumping Co2 filling machine





This machine need not be heated or cooled and CO2 can be directly filled into the fire extinguisher form the large steel cylinder. CO2 is free from influence of environmental temperature in filling;
The original pressure in the CO2 steel can is 3~ 5Mpa and the filling pressure is 6~10Mpa.
The filling speed 1~6Kg/min. Voltage 380V&220V;
Power 2.7KW.
Measurement 2600×800×900mm
   
  273*91*107cm 2.66m3
335kg
 






 
  Filling time and error table list


GTM-B
 
Carbon  
dioxide  
filler
Technical Parameters
  Working Temperature and Pressure Parameters
  of the Thermostat of the Filler
  A. Thermal uniform temperature is controlled in
    the range of 38 ºC -45 ºC with a pressure of 9-10Mpa, heater power of 6KW and voltage of 380V.
B. Cold uniform temperature is controlled in the range of -5 ºC -5 ºC with a pressure of ≤7Mpa and power source voltage of 220V.


68*62*110cm 0.46m³ 117*71*126cm 0.99m³ 149*64*61cm 0.58m³ 400kg
 
 




MDG1.7
Fire extinguisher nitrogen filler
Technical parameters
Filling pressure1.7Mpa Voltage220V Power100W Weight30kg
Overall size585X500X1000mm


68*62*110cm 0.46m³ 50

 
 
Nitrogen for extinguisher filling machine with safe protective device
Technical parameters
Filling pressure1.7Mpa Voltage220V Power100W Weight30kg
Overall size585X500X1000mm

68*62*110cm 0.46m³ 50
 


 
  MDG-XB model fire extinguisher N2 filling and gauge check machine is invited by our company for N2 filling and pressure gauge check.


MDG-XB
Nitrogen filling and timing machine
Technical parameters Pressure1.7Mpa Power100W Voltage220V Weight30kg
Overall size585X500X1000mm
   
  68*62*110cm 0.46m³ 50
 



 
  Technical parameters Voltage220V Power2KW Weight75kg
Overall size1000X462X1100mm
   
  110*58*83cm 0.53m³ 73
MDH-11
 
 
     
 




XBY
Fire extinguisher check device
Technical parameters Pressure1.7Mpa Voltage220V Power100W Weight30kg
Overall size585X500X1000mm


 

 




MQS
Fire
Specifications
Overall size 1080X850X900mm Weigt95Kg
Voltage380V or 220V Temperature 0ºC to 1000ºC
Power4 to 8KW
extinguisher  
airtight test  
box 100*80*120cm 0.96m³ 100kg
 







 










Testing-Pressu re test stand
This machine is used to test the cylinder pressure and it is consisted of hydraulic pressure test pump and test stand. The hydraulic test pump can be different types according to requirement. The machine showed in the pictures has three connectors. We can also supply machine of different connectors according to requirement. The connector divided to quick link connector and quick testing connector.
Technical parameters
Max. test pressure40Mpa Test capacity20pcs/hour Voltage380V Power1.1KW Weight220kg
Overall size 655X480X1055mm 950X650X1200mm
 



 







Test pressure and cleaning
Technical parameters Adjustable pressure1-6Mpa Water flow10L/min
Test capacity50pcs/hure Voltage220V Power1.3KW Weight185kg
Overall size1635X650X1340mm
machine
174*82*140cm 2.0m³ 185
   
 





Water type extinguisher filling
Technical parameters Filling precision1kg≤±0.015 Filling speed6kg/min Voltage220V
Power90W
Volume of liquid tand50L Weight45kg
Overall size600X580X950mm
machine
75*76*107cm 0.6m³ 105
 
 



Fire extinguisher clamper
This clamper is controlled by air cylinder for fire extinguisher cylinder clamping.
Specifications
Overall size670X200X250mm Clamping diameter80 to 180mm Air cylinder distance 150mm
Air source pressure0.6Mpa to 0.8Mpa
(pneumatic)  
  φ80-180 mm 79*32*35 0.08m³ 25kg
 
    This machine is operated by hand for the fire
  extinguisher clamping.

Fire

φ80-φ180 mm 94*41*38 0.15 45kg
   
clamper  
(manual)  

Automatic Type Fire Extinguisher Powder Filler Gfm8-2 (Carbon Dioxide Filling Machine .

Fire Extinguisher Carbon Dioxide Filling Machine Firefighting Equipment

tictrucks.en.made-in-china.com 

Carbon Dioxide Filling Machine GTM-B Operation And Use Process Manuals  Operation process
1. Open the package and check the accessories
2. Connect the power cord, the connection line between the devices
3. Prepare the equipment and connect the cable. It is recommended to connect and place in this way as photo.
4. Open the upper cover of the refrigeration cabinet. Be sure to open it slowly. Pay attention not to break the connecting wire inside. Then add antifreeze into the inside. The liquid level can be seen at the back of the machine. Add it to the specified position.
Note: Do Not Break The Inner Connecting Wire
5. Set the heating temperature, which is used to heat the temperature of the water tank of the air source bottle. Heating the air source bottle helps to increase the pressure of the air source and the filling speed, as shown in the figure
To set the timing, adjust the button from position 1 to position 2, and then turn the right knob to increase the temperature clockwise and decrease the temperature by turning it anticlockwise. It is recommended to set the temperature about 45 degrees. After the temperature is set, adjust the setting button from 2 to 1.
6. Set the refrigeration temperature. After heating the air source bottle, the pressure will rise to drive carbon dioxide into the refrigerator. After entering the refrigerator, the pressure will be reduced, resulting in pressure difference, which is helpful for carbon dioxide filling. It is suggested that the refrigeration temperature should be set from 0 ºC to - 5 ºC.
7. The most Important -difficult part is to set the filling weight
(1)First, mark 1234 key in the electronic meter from left to right
(2) Click the "1" key and 0.000 will appear directly
(3) Click "4", and the L value setting will appear directly
(4)Click "3" key, light move left and right, you can choose to change the position of the number, the position that needs to be changed is the adjustment position
(5) Click key "2" to cycle up and down, set the weight to be filled, and number up and down circulation.
(6) According to the customer's different needs, through the 2 and 3 keys, left and right shift, up and down shift to adjust the position of the decimal point and the size of the number, left and right cycle, up and down cycle to complete the target weight setting. Then click 4 to save the set weight. After setting the weight, when filling the fire extinguisher in the future, the filling will stop automatically at this weight.
8.Prepare to start filling. After the heating temperature reaches the set temperature and the refrigeration temperature reaches the set temperature, start filling.
8.1 Open The Air Source Bottle
8.2 Open the inflation valve connected to the fire extinguisher and let the air in the machine be discharged from the inflation nozzle until the white fog is carbon dioxide. Close the inflation valve, add the fire extinguisher, press down the valve handle of the fire extinguisher, fix it, and then put it on the electronic scale for filling.
8.3 After connecting the fire extinguisher Put it to the electronic scale, click the   "1" key on the display to remove the net weight and clear to zero, then prepare to fill.
Click the filling on button, and the machine will automatically fill carbon dioxide. When the display weight reaches the set weight, the machine will stop automatically, take down the fire extinguisher, this one fire extinguisher filling is completed. Repeat this operation to fill other same fire extinguishers. Automatic Filling Fire Extinguisher GFM8-2 Operation manuals Operation process
1,Open the package and check the accessories
2. Connect the discharge port of filter barrel
3. Connect the scale and ground wire
4. To prepare the powder source, you can prepare the powder storage funnel by yourself, or put the powder suction tube into the powder bag directly
Note: there are two powder inlet pipes on the back of the machine and two powder discharge pipes on the front of the machine,
5. An empty fire extinguisher cylinder is placed under the filter barrel. The bottle mouth of the fire extinguisher is connected and sealed by lifting the filter barrel by lifting the hand wheel. At the same time, the butterfly valve at the discharge port is opened. The function is to recover the dry powder dispersed during the filling process, so that there is no dust floating during vacuum filling.
6. Connect the front filling end cover of the filling machine
Two powder feeding pipes, one for use and one for standby, should be one by one corresponding to the position of the powder feeding pipe on the back of the powder feeder. Turn on the mechanical main power switch after connection.
7. The most important -difficult part is to set the filling weight
(1) First, mark 1234 key in the electronic meter from left to right
(2)Click the 1 key and 0.000 will appear directly
(3) Click 3, and  "d"  will appear directly
(4) Click the 4 key and 0 will appear directly
(5) Click the 2 key and 1 will appear directly
(6)Click key 4. This operation is very important. At this time, the target weight value to be filled is officially set, which is also the dividing line of the operation setting weight. The steps before this operation are fixed. You must operate in this way. After this interface appears, the operation will adjust itself according to the required weight. Remember the formula of the above key sequence: 1-3-4-2-4
https://tictrucks.en.made-in-china.com 

(7)Next, it is more flexible to set the target filling weight. According to the customer's different needs, the position of the decimal point and the size of the number can be adjusted by shifting from left to right, up and down according to the customer's different needs, and the target weight can be set through the left and right circulation, up and down circulation.

(8)After setting the target weight, continue to click 4 to save. This operation is saved as permanent until the next time you modify the set weight. 
tictrucks.en.made-in-china.com 
(9)In the last step, click 1 key
(quickly) twice continuously to display the interface to 0.000
8. Prepare the filled fire extinguisher, put on the filling end cover, and then put it on the electronic scale. Click the 1 button to let the electronic scale display 0.000. Before filling, check the opening status of the valve under the filter barrel and the valve of the powder feeding pipeline.


Check and confirm the mechanical button before filling

(1)The rightmost button is rotated to the "FILLING" position
(2)The leftmost button is also rotated to the "FILLING" position
9. Officially start filling operation

(1)Step 1: click the button "Machine Running"
(2) In the second step, click the"Filling Start" button to start the automatic powder suction and filling, and the filling stops automatically when the filling reaches the set target filling weight.
(3) After the automatic filling stops, take down the filling end cover on the fire extinguisher, remove the filled fire extinguisher, replace the empty bottle of the fire extinguisher with a new one, cover the end cover, and continue to click the "Filling Start" button to continue filling, and repeat the operation.

10. Equipment maintenance and pipeline cleaning process
When it is found that the filling speed slows down during the filling process, or after continuous filling of 30 kg dry powder (about 7 pcs 4kg dry powder fire extinguishers), clean the whole pipeline of the equipment.
tictrucks.en.made-in-china.com 
The specific operation process is as follows:

(1)Manually close the valve of powder feeding pipeline
(2) Turn the right most knob on the front of the powder feeder from "FILLING" indicator key to "CLEANING" indicator key, and the cleaning indicator light is on at the same time.
(3) This equipment is an automatic cleaning device. It should be cleaned once every 3-4 seconds. It is recommended to clean it two or three times.
(4) After cleaning, turn the "CLEANING" indicator key to "FILLING" indicator key, and open the powder feeding pipeline valve to continue the filling and powder filling operation procedure.
 Hereafter:, all operations repeat the previous work. When the working time of the day is up, click the "MACHINE STOP" button before work, and then turn off the main power switch to complete the work of the day.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now