Customization: | Available |
---|---|
After-sales Service: | 24hours |
Warranty: | 24months |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Quick Detection Laboratory Mobile Container PCR LabPolymerase Chain Reaction Mobile Container PCR Lab Gene Amplification LaboratoryMobile Cabin PCR Lab
Dong Run Mobile Cabin PCR Rapid Detection Molecular Laboratory Mobile Bio-safety Unit
Configure | Introduction | Quantity | Unit | ||
1 | Box structure | 1. The wall is made of 2mm thick reinforced wave steel plate, and the ground plate is made of 3mm thick reinforced wave steel plate, which is suitable for various terrain transportation conditions; 2. Adopt 6mm thick high quality steel support frame, stable and durable; 3. Equipped with lifting clamps to meet the transportation needs and with box stacking function; 4. High strength outer door, good sealing performance, strong and durable, suitable for all-weather use conditions; 5. The surface is treated with rust removal, antirust paint and three times of fluoronitrogen paint, all-weather and durable. |
1 | set | |
2 | Box inner structure | 1. The 50 mm thick laboratory special antibacterial purification board is used for partition and ceiling, the thickness of the board is 0.526 mm, with good antibacterial effect, good fire prevention, moisture-proof, anti degumming, high strength, heat preservation, heat insulation, sound absorption and other characteristics; 2. The internal and external corners of the box body are equipped with arc-shaped aluminum profiles for cleaning room, to ensure that the inside of the box body is smooth and free of sanitary dead angle, ash deposition and mold; 3. The doors and windows are assembled with antibacterial purification plate and toughened glass to ensure the transparency and lighting effect in the box; the external windows are set as ventilatable structure according to the requirements of biosafety laboratory; the safety doors are equipped to facilitate the placement of instruments and equipment; 4. The ground is made of 3mm rubber floor with homogeneous transparent core, which is fireproof, antibacterial, wear-resistant and antiskid; 5. Equipped with LED embedded clean light, energy saving and easy to maintain; 6. Equipped with special UV lamp for laboratory, and equipped with delay function to protect the personal safety of laboratory personnel; 7. The water supply and drainage lines and electrical lines in the box are orderly distributed, hidden and installed, and high-quality brand materials are used; 8. The tank is equipped with a water supply tank and a drainage tank, which can maintain the normal operation of the laboratory in case of water shortage; 9. The generator set can be selected in the cabinet to maintain the normal operation of the laboratory in the extreme case of power failure. |
1 | set | |
3 | Laboratory cabinet | 1, the use of laboratory antibacterial double-sided membrane panel, corrosion resistance, weather resistance, strong antibacterial capacity; 2. The cabinet body is made of 1.2m m thick high-quality steel plate. After degreasing, water washing, pickling, water washing, neutralization, phosphating, water washing, high-pressure washing, drying and other procedures, the surface is sprayed with epoxy resin spray powder for high-temperature curing. The thickness of the coating is more than 75 μ m, corrosion-resistant and weather resistant. 3. Water and electricity accessories are made of high-quality laboratory brand, equipped with laboratory faucet, PP sink, eye washer, etc |
20 | m | |
4 | HVAC engineering | 1. The ventilation and exhaust system shall be designed by the laboratory specialty according to the P2 + standard biosafety laboratory to ensure the air volume of the clean room and the set air change times, and ensure the stable step pressure difference of each room; 2. The ventilation and exhaust system adopts high anti-corrosion materials, and the exhaust system is filtered by a special system to meet the requirements of normal outdoor discharge; 3. Equipped with fresh air conditioning system, the design of fresh air conditioning plus multi line air conditioning is adopted to filter and regulate the temperature of fresh air, meeting the all-weather use conditions of - 30 ° to 40 ° and ensuring constant indoor temperature; |
1 | set | |
20kW generator set, ensure normal operation under power failure, increase cost | |||||
Unit Total amount | Box Container Unit | ||||
The following is a list of optional instruments equipment (Price add CNY) | |||||
1 | 2-8 ºC and - 20 ºC refrigerators |
Main parameters: Effective volume: 80 Temperature range: 2 ~ 8 Internal dimension: 360 * 400 * 680 External dimension: 472 * 500 * 870 |
1 | set | |
2 | Mixer | Main parameters: Operation mode: jog Speed range: 2800 rpm Motor power: 58w External dimension: 130x80x130 (mm) |
1 | set | |
3 | One set of pipette (5 sets) | Without pipette rack | 2 | set | |
4 | Ordinary centrifuge | Main parameters: Maximum speed: 5000r / min Maximum capacity: 800ml Overall dimension 490 * 400 * 370mm Weight: 40kg |
1 | set | |
5 | Super clean platform | 1 | set | ||
6 | 2-8 ºC and - 20 ºC refrigerators | Main parameters: Effective volume: 147 Temperature in the box: - 15 ~ - 25 ºC Boundary dimension: 739 × 564 × 837 Internal dimension: 599 × 389 × 677 |
1 | set | |
7 | High speed centrifuge | Main parameters: Maximum capacity: 400ml Maximum speed: 16600r / min Boundary dimension: 400 × 350 × 340mm Weight: 20kg |
1 | set | |
8 | Thermo Cell | Main parameters: Temperature control range: room temperature + 5 ºC - 100 ºC Time setting: maximum 99h59min Temperature stability @ 100 ºC: ± 0.5 ºC Display accuracy: ± 0.1 ºC Size (mm): 270x190x170 Net weight: 2.5kg |
1 | set | |
9 | Biosafety cabinet | Full row, overall dimension: 1530 × 800 × 1950mm Weight: 350 kg |
1 | set | |
10 | Plate centrifuge / eight row centrifuge | 1 | set | ||
11 | Nucleic acid purifier | Boundary dimension: 430 * 495 * 435 weight: 32.5kg | 1 | set | |
12 | Oscillating mixer | 1 | set | ||
13 | Real time PCR | Shape 384 * 353 * 348mm weight 13kg | 1 | set | |
14 | computer | 1 | set | ||
15 | UPS | One hour after power failure, Santak c3k (3KVA / 2.4kw internal battery) |
1 | set | |
16 | Mobile UV lamp | 4 | set | ||
17 | Automatic hybridizer | Overall dimension (L x W x H): 420x380x380 (mm) net weight: 21kg | 1 | set | |
18 | Mobile UV lamp | 1 | set | ||
19 | Vertical pressure steam sterilizer | Overall dimension:425*425*660MM Weight: 19kg, portable 24L |
1 | set | |
Instruments | Total Instruments | ||||
20 | Trailer | 17.5*3*1.5m | 1 | set | |
Total |
Unit Total amount | Box Container Unit | |||
Instruments | Total Instruments | ||||
FOB China PORT |
This BSL-2 Mobile Lab is highly suited for a range of applications including:
- Rapid response for epidemics or potential outbreaks of disease
- Agricultural, Veterinary and Public Health Surveillance
- Environmental sampling and testing
- Forensics and rapid on-site capabilities for law enforcement
- Advanced capabilities for First-Responder and Hazmat operations
- Disaster management capabilities for regional and national agencies
- On-site threat assessment to detect and identify suspicious or unknown materials
Significance of Mobile Container PCR Labs
High Timeliness - When the epidemic occurs, the mobile container PCR labs can be quickly transported to the outbreak site to carry out the detection, which brings out the better epidemic control.
Good Benefits - In the outbreak, a large number of PCR labs need to be built. While after the outbreak, those idle PCR laboratories can causes huge waste. Mobile container PCR labs can just solved this problem on the premise of meeting urgent needs. When an epidemic occurs nearby (within 100 kilometers), it can be quickly trans- ported to the outbreak site and provided to healthcare staffs to complete the testing work. If there is no need any longer, it can be properly maintained until next time.
Reduce Transmission Range - The mobile container PCR labs can be easily transported to the outbreak site of epidemic, which means the reduction of the flow of patients, and the route and time of virus transmission, thus the outbreak can be well controlled.
Reduce Sample Circulation Time - Due to the shortage of testing staffs and facilities, or other problems such as longterm delivery time, preliminary screens usually have to be carried out with one or two days delay. They also cause the obvious difference of the virus nucleic acid test results on the same sample, which means the enlarged error and less accuracy. If the processing time can be shortened, the accuracy will be improved greatly, the testing time of pathogen will be less, and the distance of virus circulation will be reduced. All of those will contribute to control of the epidemic in positive roles.
PCR Lab Mobile Container PCR Laboratory
Mobile Cabin PCR Lab
Movable Container PCR Lab Supplier
Mobile Cabin PCR Lab Equipment
Polymerase Chain Reaction Mobile Container PCR Lab Gene Amplification Laboratory
Quick Detection Laboratory Mobile Container PCR Lab
Quick Detection Laboratory Mobile Container PCR Lab
Mobile Container Lab Furniture for PCR Lab Dection
Advantage | Less space, easier installation, better pollution control, renewable resourse, more safety |
The container laboratory is a relatively new building system, which is transformed from a traditional cargo container, but with a value-added use of them. It is characterized as hige mobility, and very strong, which can withstand great pressure. The basice installation can be completed in the factory, and the finished products can be transported to the site and lifted to the position. It can be put into urgent use immediately after the finish of water and electricity connection, which provides a very convenient solution. The mobile container PCR labs can be reused repeatedly, easy to dissemble and install, have the superior capability and stability with good resistance to shock. It costs relatively low, but has the high performance safety, which reflects the current concepts of "green environmental protection, low carbon emission and energy saving" of the world. | |
Principles and Requirements |
High site requirements, high personnel requirements, High risk during detection, high protection requirements, high demands on physical endurance. |
The PCR laboratory is also called the gene amplification laboratory. PCR is short for Polymerase Chain Reaction, which is a molecular biology technique used to amplify a specific piece of DNA. It can be viewed as a specific DNA copy produced outside the body of an organism. By the means of the DNA gene-tracking system, the amount of virus in a patient's body can be quickly measured with the accuracy on nanoscale. It can answer many questions, such as whether the virus replicates, whether it is contagious, how strong the infectivity is, whether it is necessary to take medicine, and whether there are abnormal changes in organ function. Furthermore, such information can help us to judge which kind of antiviral drugs are most suitable for patients, how effective the drugs are, and provide a reliable test basis for clinical treatment. |
Functional Chamber |
Minimum Number of Air Changes per Hour |
Minimum Pressure Difference between Adjacent Rooms and Outdoor Space (Pa) |
Temperature (ºC) |
Relative Humidity (%) |
Noise Db(A) |
Buffer Zone (I) * | 12 | +5 | 18-26 | 30-70 | <60 |
Reagent Storage and Preparation |
15 | +10 | 18-26 | 30-70 | <60 |
Sample Preparation |
15 | -20 | 18-26 | 30-70 | <60 |
Nucleic Acid Amplification |
15 | -20 | 18-26 | 30-70 | <60 |
Product Analysis | 15 | -20 | 18-26 | 30-70 | <60 |
Buffer Zone (II)* | 12 | -5 | 18-26 | 30-70 | <60 |
Corridor for PCR only |
12 | - | 18-26 | 30-70 | <60 |
Application location: Hopital, healthcare institue, custom.
PCR laboratory workflow: detection scope, detection process and detection quality are constantly developing and changing. In this process, the transmission route and pathogenicity of the disease have not been completely defined, and biosafety issues in the detection process and infection risk of the detection personnel need to be guided to a certain extent.
Experimental process: specimen transport and receipt-specimen pretreating-nucleic acid extraction and sampling-nucleic acid amplification
Flow direction: PCR corridor - buffer room - experimental processing room (reagent preparation room, specimen preparation room, amplification room, amplification product analysis room, decontamination room)
Article direction: reagent preparation room - specimen preparation room - amplification room - amplification product analysis room - decontamination room
Main parts:
1. Exterior&interior structure.
2. Bench&cabinet.
3. HVAC engineering.
Optional packages:
1. Generator units.
2. Air conditioning units.
3. Sewage treatment equipment.
For technical information, pls don't hesitate to keep us being informed.
The advantages of assembly-type nucleic acid test PCR laboratory construction |
|
High timeliness | When an epidemic occurs, the mobile shelter laboratory can be quickly transported to the place where the epidemic occurred for testing. The control of the epidemic will have better results. |
Good efficiency | When an outbreak occurs, a large number of PCR laboratories need to be built; after the outbreak, a large number of idle PCR laboratories cause a huge waste. The mobile box PCR laboratory just solved this problem on the premise of meeting the urgent needs, (when (Nearly 100 kilometers) If an epidemic occurs, it can be quickly transported to the place where the epidemic occurred for the inspection personnel to complete the inspection work. It really needs to be idle, and can also be put into use when it is necessary to keep it properly. |
Reduce the spread | The box PCR laboratory is transported to the place where the epidemic occurs, reducing the flow of patients, thereby reducing the path and time of virus transmission, and the epidemic will also be well controlled. |
Reduce sample transfer time | In the face of patient samples without testing personnel, no laboratory testable, or due to delivery time and other issues, the initial inspection will be delayed for a day or two, the accuracy of the viral nucleic acid is significantly different, the error will be relatively large. If the detection time can be shortened, the accuracy will be greatly improved, the detection time of the pathogen will be shortened, and the distance of the virus circulation will be shortened, which will have a fundamental effect on the control of the epidemic. |