• Customizing 40FT /45FT PCR Lab Mobile Container PCR Laboratory Mobile PCR Shelter
  • Customizing 40FT /45FT PCR Lab Mobile Container PCR Laboratory Mobile PCR Shelter
  • Customizing 40FT /45FT PCR Lab Mobile Container PCR Laboratory Mobile PCR Shelter
  • Customizing 40FT /45FT PCR Lab Mobile Container PCR Laboratory Mobile PCR Shelter
  • Customizing 40FT /45FT PCR Lab Mobile Container PCR Laboratory Mobile PCR Shelter
  • Customizing 40FT /45FT PCR Lab Mobile Container PCR Laboratory Mobile PCR Shelter

Customizing 40FT /45FT PCR Lab Mobile Container PCR Laboratory Mobile PCR Shelter

After-sales Service: 24hours
Warranty: 24months
Fuel: Diesel
Certification: ISO9000, CCC
Emission Standard: E5
Condition: New
Customization:

Contact Supplier

Diamond Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory, Trading Company, Group Corporation
  • Overview
  • Detailed Photos
  • Product Description
Overview

Basic Info.

Model NO.
Customized
Transport Package
Nil
Specification
Standard
Trademark
TMOON LAB
Origin
China
HS Code
8705909990
Production Capacity
10000

Product Description

Mobile PCR shelter Customizing 40FT /45FT PCR Lab Mobile Container PCR Laboratory Mobile PCR Shelter  Customizing 40FT /45FT PCR Lab Mobile Container PCR Laboratory

Mobile Cabin PCR Rapid Detection Molecular Laboratory Mobile Bio-safety Unit
Container Lab mobile PCR nucleic acid testing laboratory

Containerized Lab BIOSAFETY LEVEL-2 MOBILE LABORATORY

External Dimensions:17.5*3*3m (length*width*height) 
Interal Dimensions: 17.3*2.72*2.76m (length*width*height) 
Occupied Area: 52.5m2,about 7 standard car parking spaces 
Total Weights: about 15 tons

Rapid deployment to add instant testing capacity and is suited for remote locations

Mobile Laboratory

The PCR testing workflow for diagnosis involves RNA extraction, PCR setup and real-time PCR analysis. mobile container laboratory is fully self-contained and made to withstand even the harshest of climates.
The container lab is a Biosafety Level 2 (BSL-2) laboratory with a class II A2 recirculating biosafety cabinet and adheres to the guidelines set for testing by the Centres for Disease Control and Prevention (CDC).Lab technicians can work in complete protection from external conditions in a controlled and safe environment. 

Mobile PCR & Antibody Testing Laboratory

Detailed Photos

Quick Detection Laboratory Mobile Container PCR LabCustomizing 40FT /45FT PCR Lab Mobile Container PCR Laboratory Mobile PCR ShelterPolymerase Chain Reaction Mobile Container PCR Lab Gene Amplification LaboratoryCustomizing 40FT /45FT PCR Lab Mobile Container PCR Laboratory Mobile PCR ShelterMobile Cabin PCR Lab

Customizing 40FT /45FT PCR Lab Mobile Container PCR Laboratory Mobile PCR Shelter

Portable Laboratory for Molecular 

Customizing 40FT /45FT PCR Lab Mobile Container PCR Laboratory Mobile PCR Shelter
  • molecular testing laboratory
  • molecular laboratory design

Mobile Cabin PCR Lab Equipment

Customizing 40FT /45FT PCR Lab Mobile Container PCR Laboratory Mobile PCR Shelter

Images of Mobile Molecular Laboratory Vehicle

Customizing 40FT /45FT PCR Lab Mobile Container PCR Laboratory Mobile PCR Shelter

Mobile laboratoriesGeneral lab testing equipment

Customizing 40FT /45FT PCR Lab Mobile Container PCR Laboratory Mobile PCR Shelter PCR Lab Mobile Container PCR Laboratory
Customizing 40FT /45FT PCR Lab Mobile Container PCR Laboratory Mobile PCR Shelter Movable Container PCR Lab 
Customizing 40FT /45FT PCR Lab Mobile Container PCR Laboratory Mobile PCR Shelter

Mobile Molecular Testing Labs

Customizing 40FT /45FT PCR Lab Mobile Container PCR Laboratory Mobile PCR Shelter Mobile Cabin PCR Lab Equipment
Customizing 40FT /45FT PCR Lab Mobile Container PCR Laboratory Mobile PCR Shelter
Product Description

 

Dong Run  Mobile Cabin PCR Rapid Detection Molecular Laboratory Mobile Bio-safety Unit

Molecular Laboratory with PCR system house Shelters Units

Mobile Bio-safety Unit ASSY (WITHOUT VEHICLE)
 

The pictures are for your reference only. 
1, Shape and specification
External dimension of the box: 17.5 * 3 * 3 (m, L * w * h), internal dimension: 
17.3 * 2.72 * 2.76 (m, L * w * h)
Floor area of the box: 52.5m2, about 7 standard car parking spaces
Total box weight: about 15 tons 

2, Construction specification
T / cecs662g-2020, building technical standard of medical biosafety secondary Laboratory
Technical specification for integrated packing box T / ccmsa20108
Code for design of heating ventilation and air conditioning of civil buildings (gb50736)
Code for construction and acceptance of clean room gb50591
Limits for dimensions, axle loads and masses of motor vehicles, trailers and motor vehicles gb1589
High efficiency air filter (GB / t13554)
Hygienic standard for hospital disinfection gb15982
General requirements for laboratory biosafety gb19489
Technical code for building of biosafety laboratory (gb50346)
General guidelines for Biosafety in microbiological and biomedical laboratories ws233
General principles for clinical laboratory design (GB / t20469)
Basic information of general technical specifications for mobile laboratory equipment (GB / t29476)
GB / t29477 general technical specification for mobile laboratory test cabin
General test method for military shelter gjb2093
General specification for military shelter gjb6109
Test method for heat sealing strength of plastic film packaging bags (QB / t2358)
Technical code for disinfection of medical institutions WS / t367
3, Application scenario
Hospitals - independent of buildings, can greatly reduce the risk of nosocomial infection;
Disease control - it can be flexibly configured at any place where any epidemic occurs at any time;
Port rapid deployment, greatly reducing the risk of overseas import;
Third party inspection: greatly reduce the sample flow speed and improve the detection accuracy;
Strategic reserve - prevention in advance, greatly reducing the probability of virus outbreak

Container Lab Specifications

45FT - 57ft (13.9~17.5m) marine container
Three wall partitions with edge covings
3 x hygienic cleanroom doors including door closer and awning
Cleanroom viewing panels
GMP compliant walls and ceiling
Full seamless polyurethane floor covering for watertight seal
LED lighting to cleanroom standards for laboratory work
Interlocking passthrough hatch between pre- and post PCR rooms
Positive air pressure in pre-PCR with an air cascade to less positive in post-PCR
lts health lab truck
Handwash basin with medical elbow taps, soap and towel dispenser (no consumables)
Chemical resistant solid core work benches with integrated under-bench cabinets, sink unit with cold water only and overhead cupboards
4ft class II A2 recirculating biosafety cabinet commissioned and validated for BSL-2 conditions to work with oral and nasal swabs
Integrated power trunking with electrical and data outlets connect to an electrical distribution board with circuit breakers
External single-phase industrial socket to connect to external power source
   Configure  Introduction  Quantity  Unit
1 Box structure 1. The wall is made of 2mm thick reinforced wave steel plate, and the ground plate is made of 3mm thick reinforced wave steel plate, which is suitable for various terrain transportation conditions;

2. Adopt 6mm thick high quality steel support frame, stable and durable;

3. Equipped with lifting clamps to meet the transportation needs and with box stacking function;

4. High strength outer door, good sealing performance, strong and durable, suitable for all-weather use conditions;

5. The surface is treated with rust removal, antirust paint and three times of fluoronitrogen paint, all-weather and durable.
1 set
2 Box inner structure 1. The 50 mm thick laboratory special antibacterial purification board is used for partition and ceiling, the thickness of the board is 0.526 mm, with good antibacterial effect, good fire prevention, moisture-proof, anti degumming, high strength, heat preservation, heat insulation, sound absorption and other characteristics;

2. The internal and external corners of the box body are equipped with arc-shaped aluminum profiles for cleaning room, to ensure that the inside of the box body is smooth and free of sanitary dead angle, ash deposition and mold;

3. The doors and windows are assembled with antibacterial purification plate and toughened glass to ensure the transparency and lighting effect in the box; the external windows are set as ventilatable structure according to the requirements of biosafety laboratory; the safety doors are equipped to facilitate the placement of instruments and equipment;

4. The ground is made of 3mm rubber floor with homogeneous transparent core, which is fireproof, antibacterial, wear-resistant and antiskid;

5. Equipped with LED embedded clean light, energy saving and easy to maintain;

6. Equipped with special UV lamp for laboratory, and equipped with delay function to protect the personal safety of laboratory personnel;

7. The water supply and drainage lines and electrical lines in the box are orderly distributed, hidden and installed, and high-quality brand materials are used;

8. The tank is equipped with a water supply tank and a drainage tank, which can maintain the normal operation of the laboratory in case of water shortage;

9. The generator set can be selected in the cabinet to maintain the normal operation of the laboratory in the extreme case of power failure.
1 set
3 Laboratory cabinet 1, the use of laboratory antibacterial double-sided membrane panel, corrosion resistance, weather resistance, strong antibacterial capacity;

2. The cabinet body is made of 1.2m m thick high-quality steel plate. After degreasing, water washing, pickling, water washing, neutralization, phosphating, water washing, high-pressure washing, drying and other procedures, the surface is sprayed with epoxy resin spray powder for high-temperature curing. The thickness of the coating is more than 75 μ m, corrosion-resistant and weather resistant.

3. Water and electricity accessories are made of high-quality laboratory brand, equipped with laboratory faucet, PP sink, eye washer, etc
20 m
4 HVAC engineering 1. The ventilation and exhaust system shall be designed by the laboratory specialty according to the P2 + standard biosafety laboratory to ensure the air volume of the clean room and the set air change times, and ensure the stable step pressure difference of each room;

2. The ventilation and exhaust system adopts high anti-corrosion materials, and the exhaust system is filtered by a special system to meet the requirements of normal outdoor discharge;

3. Equipped with fresh air conditioning system, the design of fresh air conditioning plus multi line air conditioning is adopted to filter and regulate the temperature of fresh air, meeting the all-weather use conditions of - 30 ° to 40 ° and ensuring constant indoor temperature; 
1 set
    20kW generator set, ensure normal operation under power failure, increase cost    
  Unit Total amount  Box Container Unit    
         
The following is a list of optional instruments equipment (Price add CNY) 
1  2-8 ºC and 
- 20 ºC refrigerators
Main parameters:

Effective volume: 80

Temperature range: 2 ~ 8

Internal dimension: 360 * 400 * 680

External dimension: 472 * 500 * 870
1 set
2 Mixer Main parameters:

Operation mode: jog

Speed range: 2800 rpm

Motor power: 58w

External dimension: 130x80x130 (mm)
1 set
3 One set of pipette (5 sets)  Without pipette rack 2 set
4 Ordinary centrifuge Main parameters:

Maximum speed: 5000r / min

Maximum capacity: 800ml

Overall dimension 490 * 400 * 370mm

Weight: 40kg
1 set
5 Super clean platform   1 set
6 2-8 ºC and - 20 ºC refrigerators Main parameters:

Effective volume: 147

Temperature in the box: - 15 ~ - 25 ºC

Boundary dimension: 739 × 564 × 837

Internal dimension: 599 × 389 × 677
1 set
7 High speed centrifuge Main parameters:

Maximum capacity: 400ml

Maximum speed: 16600r / min

Boundary dimension: 400 × 350 × 340mm

Weight: 20kg
1 set
8 Thermo Cell Main parameters:

Temperature control range: room temperature + 5 ºC - 100 ºC

Time setting: maximum 99h59min

Temperature stability @ 100 ºC: ± 0.5 ºC

Display accuracy: ± 0.1 ºC

Size (mm): 270x190x170

Net weight: 2.5kg
1 set
9 Biosafety cabinet Full row, overall dimension: 1530 × 800 × 1950mm

Weight: 350 kg
1 set
10 Plate centrifuge / eight row centrifuge   1 set
11 Nucleic acid purifier Boundary dimension: 430 * 495 * 435 weight: 32.5kg 1 set
12 Oscillating mixer   1 set
13 Real time PCR  Shape 384 * 353 * 348mm weight 13kg 1 set
14 computer   1 set
15 UPS One hour after power failure,

Santak c3k (3KVA / 2.4kw internal battery)
1 set
16 Mobile UV lamp   4 set
17 Automatic hybridizer Overall dimension (L x W x H): 420x380x380 (mm) net weight: 21kg 1 set
18 Mobile UV lamp   1 set
19 Vertical pressure steam sterilizer Overall dimension:425*425*660MM
Weight: 19kg, portable 24L
1 set
     Instruments    Total Instruments     
20 Trailer 17.5*3*1.5m 1 set
Total
 
Unit Total amount Box Container Unit    
  Instruments Total Instruments    
    FOB China PORT    
mobile box PCR laboratory
Hot Tags : Mobile PCR Laboratory 
Nucleic Acid Testing Laboratory
Assembly Nucleic Acid Testing PCR Laboratory

This BSL-2 Mobile Lab is highly suited for a range of applications including:

- Rapid response for epidemics or potential outbreaks of disease
- Agricultural, Veterinary and Public Health Surveillance
- Environmental sampling and testing
- Forensics and rapid on-site capabilities for law enforcement
- Advanced capabilities for First-Responder and Hazmat operations
- Disaster management capabilities for regional and national agencies
- On-site threat assessment to detect and identify suspicious or unknown materials

Significance of Mobile Container PCR Labs

High Timeliness - When the epidemic occurs, the mobile container PCR labs can be quickly transported to the outbreak site to carry out the detection, which brings out the better epidemic control.

Good Benefits - In the outbreak, a large number of PCR labs need to be built. While after the outbreak, those idle PCR laboratories can causes huge waste. Mobile container PCR labs can just solved this problem on the premise of meeting urgent needs. When an epidemic occurs nearby (within 100 kilometers), it can be quickly trans- ported to the outbreak site and provided to healthcare staffs to complete the testing work. If there is no need any longer, it can be properly maintained until next time.

Reduce Transmission Range - The mobile container PCR labs can be easily transported to the outbreak site of epidemic, which means the reduction of the flow of patients, and the route and time of virus transmission, thus the outbreak can be well controlled.

Reduce Sample Circulation Time - Due to the shortage of testing staffs and facilities, or other problems such as longterm delivery time, preliminary screens usually have to be carried out with one or two days delay. They also cause the obvious difference of the virus nucleic acid test results on the same sample, which means the enlarged error and less accuracy. If the processing time can be shortened, the accuracy will be improved greatly, the testing time of pathogen will be less, and the distance of virus circulation will be reduced. All of those will contribute to control of the epidemic in positive roles.
 PCR Lab Mobile Container PCR Laboratory
Mobile Cabin PCR Lab
 Movable Container PCR Lab Supplier
  Mobile Cabin PCR Lab Equipment
Polymerase Chain Reaction Mobile Container PCR Lab Gene Amplification Laboratory
 Quick Detection Laboratory Mobile Container PCR Lab
Quick Detection Laboratory Mobile Container PCR Lab
 Mobile Container Lab Furniture for PCR Lab Dection

Advantage Less space, easier installation, better pollution control, renewable resourse, more safety
The container laboratory is a relatively new building system, which is transformed from a traditional cargo container, but with a value-added use of them. It is characterized as hige mobility, and very strong, which can withstand great pressure. The basice installation can be completed in the factory, and the finished products can be transported to the site and lifted to the position. It can be put into urgent use immediately after the finish of water and electricity connection, which provides a very convenient solution. The mobile container PCR labs can be reused repeatedly, easy to dissemble and install, have the superior capability and stability with good resistance to shock. It costs relatively low, but has the high performance safety, which reflects the current concepts of "green environmental protection, low carbon emission and energy saving" of the world.
 
Principles and
Requirements
High site requirements, high personnel requirements, High risk during detection, high protection requirements, high demands on physical endurance.
The PCR laboratory is also called the gene amplification laboratory. PCR is short for Polymerase Chain Reaction, which is a molecular biology technique used to amplify a specific piece of DNA. It can be viewed as a specific DNA copy produced outside the body of an organism. By the means of the DNA gene-tracking system, the amount of virus in a patient's body can be quickly measured with the accuracy on nanoscale. It can answer many questions, such as whether the virus replicates, whether it is contagious, how strong the infectivity is, whether it is necessary to take medicine, and whether there are abnormal changes in organ function. Furthermore, such information can help us to judge which kind of antiviral drugs are most suitable for patients, how effective the drugs are, and provide a reliable test basis for clinical treatment.
 
Functional
Chamber
Minimum
Number of Air
Changes per
Hour
Minimum Pressure
Difference between
Adjacent Rooms and
Outdoor Space (Pa)
Temperature
(ºC)
Relative
Humidity (%) 
Noise Db(A)
Buffer Zone (I) *  12 +5 18-26 30-70 <60
Reagent Storage
and Preparation
15 +10 18-26 30-70 <60
Sample
Preparation
15 -20 18-26 30-70 <60
Nucleic Acid
Amplification
15 -20 18-26 30-70 <60
Product Analysis 15 -20 18-26 30-70 <60
Buffer Zone (II)*  12 -5 18-26 30-70 <60
Corridor for PCR
only
12 - 18-26 30-70 <60

Application location:  Hopital, healthcare institue, custom.

PCR laboratory workflow: detection scope, detection process and detection quality are constantly developing and changing. In this process, the transmission route and pathogenicity of the disease have not been completely defined, and biosafety issues in the detection process and infection risk of the detection personnel need to be guided to a certain extent.

Experimental process: specimen transport and receipt-specimen pretreating-nucleic acid extraction and sampling-nucleic acid amplification

Flow direction: PCR corridor - buffer room - experimental processing room (reagent preparation room, specimen preparation room, amplification room, amplification product analysis room, decontamination room)

Article direction: reagent preparation room - specimen preparation room - amplification room - amplification product analysis room - decontamination room

Main parts:
1. Exterior&interior structure.
2. Bench&cabinet.
3. HVAC engineering.

Optional packages:
1. Generator units.
2. Air conditioning units.
3. Sewage treatment equipment.


For technical information, pls don't hesitate to keep us being informed.


The advantages of assembly-type nucleic acid test PCR laboratory construction
 
High timeliness
When an epidemic occurs, the mobile shelter laboratory can be quickly transported to the place where the epidemic occurred for testing. The control of the epidemic will have better results.
 
Good efficiency
When an outbreak occurs, a large number of PCR laboratories need to be built; after the outbreak, a large number of idle PCR laboratories cause a huge waste. The mobile box PCR laboratory just solved this problem on the premise of meeting the urgent needs, (when (Nearly 100 kilometers) If an epidemic occurs, it can be quickly transported to the place where the epidemic occurred for the inspection personnel to complete the inspection work. It really needs to be idle, and can also be put into use when it is necessary to keep it properly.
 
Reduce the spread
The box PCR laboratory is transported to the place where the epidemic occurs, reducing the flow of patients, thereby reducing the path and time of virus transmission, and the epidemic will also be well controlled.
 
Reduce sample transfer time
In the face of patient samples without testing personnel, no laboratory testable, or due to delivery time and other issues, the initial inspection will be delayed for a day or two, the accuracy of the viral nucleic acid is significantly different, the error will be relatively large. If the detection time can be shortened, the accuracy will be greatly improved, the detection time of the pathogen will be shortened, and the distance of the virus circulation will be shortened, which will have a fundamental effect on the control of the epidemic.

Send your message to this supplier

*From:
*To:
avatar Mr. Tom King
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now